28
No display on console
Possible causes:
1. Breaker is damaged.
2. ON/OFF switch is damaged.
3. Incline power board is damaged
4. 20-pin console cable is damaged
5. PCB is damaged
Fix:
1. Inspect the circuit breaker to see if it has tripped off.
(If it is tripped off….like diagram
B
, reset the breaker. And check which
part is short-circuited. Then replace the short-circuited part.)
A
B
2. The switch is turned to the "ON" position.
( If the switch light isn't lit, replace the switch.)
2-1 Verify wire connection
AC1
&
AC2
on the MCB
.
(Please refer the” MCB WIRING” ……page 10)
3. Verify the MCB whether supply the +12VDC for console.
(Please refer the” MCB WIRING” ……page 15)
4. Replace 20-pin console cable .
5. Replace PCB
Содержание T8000PRO
Страница 1: ...1 Johnson T8000PRO SERVICE MANUAL...
Страница 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Страница 9: ...9 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Страница 12: ...12 CNT8 Console cable...
Страница 13: ...13 CNT6 Inverter cable...
Страница 15: ...15 J2 Right key cable...
Страница 16: ...16 J1 Left key cable...
Страница 17: ...17 J4 Display board cable...
Страница 18: ...18 J8 HR board cable...
Страница 19: ...19 T8000PRO Electrical block diagram for 110V...
Страница 20: ...20 T8000PRO Electrical block diagram for 220V...
Страница 21: ...21 SECTION 3 CONSOLE FUNCTIONAL FLOW DIAGRAM...
Страница 22: ...22 OPERATING T8000PRO MANUAL...
Страница 25: ...25 SECTION 4 Incline power board LED INSTRUCTIONS...
Страница 27: ...27 SECTION 5 TROUBLESHOOTINGS...
Страница 40: ...40 SECTION 5 STEPS FOR SETTING UP THE INVERTER...
Страница 41: ...41...
Страница 42: ...42...
Страница 43: ...43...
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48...
Страница 49: ...49...