Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description
Cause of anomaly
Countermeasures
B2
Front and back
overload
Front and back motor
current is too high
1. Check if the machine core structure is seized
2. Replace machine core
B3
Up and down
overload
Up and down motor
current is too high
1. Check if the machine core structure is seized
2. Replace machine core
C0
Abnormal
heating
Abnormal heater band
Please refer to warming function anomaly in
troubleshooting (4-6)
C1
Abnormal
thermistor
Abnormal thermistor
Please refer to warming function anomaly in
troubleshooting (4-6)
3-5. Error code (B2, B3, C0, C1)