www.johnsonsystems.com
26
33. POLARITY
Set the PWM output control polarity. Locked for factory use only!
This menu is only used when swapping the MADD-24 controller between different
models of JS-ICON
™
Series dimmer racks.
Press EXECUTE to enter the menu and configure the polarity mode.
DISABLED
This menu is for factory use, and is disabled for the end user.
ENABLED
Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 second.
MODE:1
Press MENU (
) to select mode 1 - for JS-ICON
™
1220 operation.
MODE:2
Press MENU (
) to select mode 2 - for JS-ICON
™
1210/620 operation.
MODE:3
Press MENU (
) to select mode 3 (not applicable with JS-ICON
™
product).
MODE:4
Press MENU (
) to select mode 4 - for JS-ICON
™
2410 operation.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 2 minutes of inactivity and save.
34. LINE V
View the RMS line voltage for each power phase.
Press EXECUTE to enter the menu and view the line voltage of each phase.
ØA=120.0
Shows the line voltage of Phase A.
ØB=120.0
Press MENU (
) to view the line voltage of Phase B.
ØC=120.0
Press MENU (
) to view the line voltage of Phase C.
Press ESCAPE or RESET to exit the menu.
35. LINE F
View the line frequency of phase A.
60.0 Hz
Shows the frequency.
36. REM TEMP
View the temperature of the remote temperature sensor.
A thermostat measures the internal heat sink temperature.
+032°F
Shows the temperature in degrees Fahrenheit.
+000°C
Press EXECUTE to toggle units to degrees Celsius.
37. CTL TEMP
View the temperature of the microcontroller.
+91°F
Shows the temperature in degrees Fahrenheit.
+33°C
Press EXECUTE to toggle units to degrees Celsius.
38. RTIME
View the total run time of the microcontroller.
The run time counter keeps track of the total time the microcontroller is powered up.
The maximum time is 99999 hours, 59 minutes, 59 seconds, or about 11.4 years.
System operation is not effected when the maximum run time is reached and can be
reset to zero at the factory.
RTIME SS
Shows the number of seconds (SS) of run time.
HHHHH:MM
Shows the number of hours (HHHHH) and minutes (MM) of run time.