background image

> English

Typical applications

The WPS pump is a five chamber posi-

tive displacement diaphragm pump. 

This pump is the ideal choice for pres-

surizing water in a closed system such 

as that found in a boat or in a recreatio-

nal vehicle.

It can easily build the pressure required 

for a pressurized water supply system.

Features

• Quiet operation

• Smooth flowing

• Self priming

• Integrated pressure switch turns

pump on and off automatically when

tap is opened and closed

• Built-in by-pass valve which reduces

the need for storage tank (only WPS

3.5)

• Dry running without damage

• Low power consumption

• Quick disconnect fittings

Working principle

As the pump runs, pressure is increased 

until it reaches the pre-defined pressure 

level, see p. 37. When the pre-defined 

pressure level is reached the integrated 

pressure switch automatically shuts the 

pump off.

The pump is equipped with positively 

checking outlet valves which ensure 

that the pressure is maintained after the 

pump shuts off.

When water is demanded (at the faucet, 

shower et.c.) the pressure decreases. 

After a moderate drop in pressure, the 

integrated pressure switch automatically 

turns the pump back on.

Due to it’s durable construction and 

thoughtful design, the pump will provide 

many years of service. 

Important!

 The pressure setting of this 

Aqua Jet WPS Water Pressure Systems 

mounted to DC motor 12/24 V 

pump is made at the factory. Warranty 

invalidated by pressure switch interfe-

rence. 

Technical description

Body:

Nylon/Polypropylene

Valve housing:  Polypropylene/Polya-

mide

Valves:

Santoprene/EPDM

Diaphragm: Santoprene

Connection: 

3/8" BSP, 1/2" hose 

  (ø 13 mm) and  

1/2" BSP, 3/4" hose 

  (ø 18 mm) or

US 3/8" NPT, 1/2"  

hose (ø 13 mm) and 

US 1/2" NPT, 3/4"  

hose (ø 18 mm)

Max. liquid

temperature: 

Max +50°C/+120°F

Fasteners: 

Stainless steel

Max. suction lift: WPS 2.9 – 2 m/6.5 ft

WPS 3.5 – 2 m/6.5 ft

WPS 4.0 – 2 m/6.5 ft

WPS 5.2 – 2,5 m/8.2 ft

Cut in pressure: see page 37

Cut-off pressure:  see page 37

(Other pressure settings see page 37)

Duty cycle: 

Intermittent, 

max 20 min 

Motor: 

WPS 2.9 – 85 W

WPS 3.5 – 85 W

WPS 4.0 – 100 W

WPS 5.2 – 150 W

12/24 V DC  

with built in thermal

protection

The motor is ignition protected accor-

ding to ISO 8846 (Small craft – Electri-

cal devices – Protection against ignition 

of surrounding flammable gases). 

Type designation 

(See page 37)

Содержание Aqua Jet WPS 2.9

Страница 1: ...IG I NAL I N STR UCTION S R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT Aqua Jet Water Pressure Systems WPS WPS 2 9 3 5 4 0 5 2 12V 24V DC I B 215 R06 10 2017 I N STR UCTION MAN UAL SE E N DE FR ES IT ...

Страница 2: ...ure decreases After a moderate drop in pressure the integrated pressure switch automatically turns the pump back on Due to it s durable construction and thoughtful design the pump will provide many years of service Important The pressure setting of this Aqua Jet WPS Water Pressure Systems mounted to DC motor 12 24 V pump is made at the factory Warranty invalidated by pressure switch interfe rence ...

Страница 3: ...en and connected to the motor base See the wiring table for correct instal lation Negative wire must be black Choose wire size in accordance with total wire lenght Pressure and capacity data based on water at 20 C 68 F and at full voltage of the motor WPS 2 9 Pressure Flow Amp draw Bar kPa Psi l min USGPM 12V 24V 0 0 0 9 4 2 4 2 5 A 1 1 A 0 4 40 5 8 8 8 2 3 3 3 A 1 4 A 0 8 80 11 6 8 1 2 1 4 0 A 1 ...

Страница 4: ...ght wire from main cable to switch to shorten the main leaders The wire connections must be sealed with a marine sealant Note Before installation with electrical control systems check that equipment to be used is of sufficient rated capacity to accept amperage draw of motor Low voltage will cause motor to overheat Maintenance The system shall be periodically sanitized using the following procedure...

Страница 5: ...e tank 2 Open all taps 3 Run pump until remaining water is expelled 4 Disconnect inlet and outlet tubes 5 Run pump briefly to confirm that water has been expelled 6 Taps shall remain open and pump fittings shall remain disconnected until temperatures are above freezing Never start a frozen pump Even if it is drained it might contain a small amount of frozen water that locks the rotor Service instr...

Страница 6: ... overheated let it cool down prior to restart 1 1 2 Check battery power supply main switch and wiring 1 1 3 Change pressure switch 1 1 4 Change pump 1 1 5 Thaw pump and system and check for damage The pump motor is liable to damage when a frozen pump is started 2 1 1 Fill up tank 2 1 2 Carefully flush pump with tap water at nominal pump flow Note Flush in nominal flow direction 2 1 3 Replace diaph...

Страница 7: ...25 28 36 22 20 18 34 34 13 12 11 23 29 40 41 26 27 21 24 33 32 15 14 14 15 19 31 9 17 27 7 V Pos A 18 29 ...

Страница 8: ...WPS 2 9 34 13 12 11 12 8 10 6 5 16 1 3 2 16 2 15 4 17 35 7 ...

Страница 9: ...25 28 27 22 20 18 33 33 36 13 12 11 23 29 17 26 27 21 24 7 32 31 15 14 14 15 19 30 27 40 39 37 38 9 35 35 26 41 42 V Pos A 18 29 ...

Страница 10: ...WPS 3 5 12 11 12 8 10 6 34 7 5 4 16 1 3 2 16 ...

Страница 11: ...10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 15 16 V Pos A 19 31 ...

Страница 12: ...9 10 11 12 4 5 6 12 Waste handling material recycling At the products end of life please dispose of the product according to appli cable law Where applicable please disassemble the product and recycle the parts material ...

Страница 13: ... WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 Check out the collection of boat parts hardware we offer ...

Отзывы: