Installation

Locate the pump in a dry location.

 

If the pump is mounted vertically, the 

motor shall face up.

Mark screw positions and drill pilot  

holes (see drilling template page 49).

Mount the pump using stainless steel 

screws and with the accompanying 

washers (over the rubber feet); taking 

care not to over compress the vibration 

dampening rubber feet.

Reinforced, high pressure flexible tubing 

is recommended. If rigid pipe is used, a 

length  (225 mm/9 inches minimum) of 

flexible tubing shall be installed between 

the pump and the rigid pipe. This will 

address noise and/or damage caused 

by vibration transmitted to rigid pipe.

Use stainless steel hose clamps to se-

cure tubing to quick disconnect fittings 

and other hose barbs in the system.

A strainer must be installed

 in line be-

fore the pump intake, to prevent debris 

from entering pump and interfering with 

proper functioning of valves.

Electrical installation 

The pump must be installed according 

to SS-EN ISO 10133 (Small craft – 

Electrical system – Extra low voltage 

DC installation for continuous current). 

Note: The fuse must be ignition protec-

ted.

The motor is equipped with built in 

thermal protection to prevent the motor 

from overheating. The protection is au-

tomatically restored when the motor  

is cooled.

If the pump is connected with separate 

earth lead, this should be yellow/green 

and connected to the motor base.

See the wiring table for correct instal-

lation. Negative wire must be black.

Choose wire size in accordance with 

total wire lenght.

Pressure and capacity data 

(based on water at +20°C/68°F and at 

full voltage of the motor)

WPS 2.9

Pressure                 Flow   

Amp. draw

Bar    kPa   Psi  l/min  USGPM  

12V  24V

9,4 

2,4 

  2,5 A  1,1 A

0,4     40  5,8     8,8 

2,3 

  3,3 A  1,4 A

0,8     80  11,6  8,1 

2,1 

  4,0 A  1,8 A

1,2  120  17,4  7,3 

1,9 

  4,6 A  2,1 A

1,6  160  23,2  6,7 

1,8 

  5,2 A  2,4 A

2,0  200  29  5,8 

1,5 

  5,8 A  2,7 A

2,4  240  29  4,9 

1,3 

  6,4 A  3,0 A

2,8  280  40,6  4,1 

1,1 

  6,9 A  3,2 A

Fuse required  

10 A   5 A

WPS 3.5

Pressure

Flow 

Amp. draw

Bar    kPa   Psi  l/min  USGPM  

12V  24V

0        0       0 

11,8  3,1 

  2,3 A 

1 A

0,5     50     7,3  10,8  2,9 

  2,7 A  1,3 A

1,0  100   14,5  10,4  2,8 

  3,5 A  1,6 A

1,5  150  21,8  9,1 

2,4 

  4,2 A  2,0 A

2,0  200  29  7,4 

  4,5 A  2,3 A

2,5  250  36,3  5,8 

1,5 

  5,8 A  2,7 A

2,65  265  38,4  5,2 

1,4 

  6,0 A  2,9 A

Fuse required  

10 A 

5 A

WPS 4.0

Pressure

Flow 

Amp. draw

Bar    kPa   Psi  l/min  USGPM  

12V  24V

0        0       0 

13 

3,4 

  2,3 A 

1A

0,4  40  5,8  12,2  3,2 

  3,1 A  1,3 A

0,8  80  11,6  11,4  3 

  4,0 A  1,7 A

1,2  120  17,4  10,6  2,8 

  4,8 A  2,1 A

1,6  160  23,2  9,9 

2,6 

  5,4 A  2,5 A

2,0  200  29  9,1 

2,4 

  6,2 A  2,8 A

2,4  240  29  8,5 

2,2 

7 A  3,1 A

2,8  280  40,6  7,7 

  8,1 A  3,6 A

Fuse required 

10 A 

5 A

WPS 5.2

Pressure                 Flow   

Amp. draw

Bar    kPa   Psi  l/min  USGPM  

12V  24V

0        0       0 

19,4     5,1 

  3,9 A  1,6 A

0,4     40     5,8  18,2  4,8 

  4,9 A  2,1 A

0,8     80     11,6  17 

4,5 

6 A  2,5 A

1,2   120   17,4  15,8  4,2 

  7,1 A  3,1 A

1,6    160   23,2  14,7  3,9 

8 A  3,6 A

2,0    200   29  13,5  3,6 

  9,2 A  4,1 A

2,4     240   29  12,2  3,2 

10,3 A  4,7 A

2,8     280   40,6  11,2  3 

11,2 A  5,1 A

Fuse required 

15 A 

8 A

Содержание Aqua Jet WPS 2.9

Страница 1: ...IG I NAL I N STR UCTION S R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT Aqua Jet Water Pressure Systems WPS WPS 2 9 3 5 4 0 5 2 12V 24V DC I B 215 R06 10 2017 I N STR UCTION MAN UAL SE E N DE FR ES IT ...

Страница 2: ...ure decreases After a moderate drop in pressure the integrated pressure switch automatically turns the pump back on Due to it s durable construction and thoughtful design the pump will provide many years of service Important The pressure setting of this Aqua Jet WPS Water Pressure Systems mounted to DC motor 12 24 V pump is made at the factory Warranty invalidated by pressure switch interfe rence ...

Страница 3: ...en and connected to the motor base See the wiring table for correct instal lation Negative wire must be black Choose wire size in accordance with total wire lenght Pressure and capacity data based on water at 20 C 68 F and at full voltage of the motor WPS 2 9 Pressure Flow Amp draw Bar kPa Psi l min USGPM 12V 24V 0 0 0 9 4 2 4 2 5 A 1 1 A 0 4 40 5 8 8 8 2 3 3 3 A 1 4 A 0 8 80 11 6 8 1 2 1 4 0 A 1 ...

Страница 4: ...ght wire from main cable to switch to shorten the main leaders The wire connections must be sealed with a marine sealant Note Before installation with electrical control systems check that equipment to be used is of sufficient rated capacity to accept amperage draw of motor Low voltage will cause motor to overheat Maintenance The system shall be periodically sanitized using the following procedure...

Страница 5: ...e tank 2 Open all taps 3 Run pump until remaining water is expelled 4 Disconnect inlet and outlet tubes 5 Run pump briefly to confirm that water has been expelled 6 Taps shall remain open and pump fittings shall remain disconnected until temperatures are above freezing Never start a frozen pump Even if it is drained it might contain a small amount of frozen water that locks the rotor Service instr...

Страница 6: ... overheated let it cool down prior to restart 1 1 2 Check battery power supply main switch and wiring 1 1 3 Change pressure switch 1 1 4 Change pump 1 1 5 Thaw pump and system and check for damage The pump motor is liable to damage when a frozen pump is started 2 1 1 Fill up tank 2 1 2 Carefully flush pump with tap water at nominal pump flow Note Flush in nominal flow direction 2 1 3 Replace diaph...

Страница 7: ...25 28 36 22 20 18 34 34 13 12 11 23 29 40 41 26 27 21 24 33 32 15 14 14 15 19 31 9 17 27 7 V Pos A 18 29 ...

Страница 8: ...WPS 2 9 34 13 12 11 12 8 10 6 5 16 1 3 2 16 2 15 4 17 35 7 ...

Страница 9: ...25 28 27 22 20 18 33 33 36 13 12 11 23 29 17 26 27 21 24 7 32 31 15 14 14 15 19 30 27 40 39 37 38 9 35 35 26 41 42 V Pos A 18 29 ...

Страница 10: ...WPS 3 5 12 11 12 8 10 6 34 7 5 4 16 1 3 2 16 ...

Страница 11: ...10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 15 16 V Pos A 19 31 ...

Страница 12: ...9 10 11 12 4 5 6 12 Waste handling material recycling At the products end of life please dispose of the product according to appli cable law Where applicable please disassemble the product and recycle the parts material ...

Страница 13: ... WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 Check out the collection of boat parts hardware we offer ...

Отзывы: