AB5 and AB51 Drivers User Manual
Technical Data
Nanomotion Ltd.
38
How It Works
5.3.5
The TP feature is designed with the following motor calculated
temperature settings:
•
Motor temperature below 85°C - normal operation.
•
Motor temperature between 85°C to 100°C - warning mode.
Displayed by a blinking TP LED and an on\off Fault output signal
(pin #3 in the 25 pin I/O port connector).
•
Motor temperature above 100°C - the motor is disabled. The TP
LED is constantly on and so is the Fault output (pin #3). The
driver remains disabled until motor temperature drops to 85°C
(natural cooling).
•
Motor temperature back under 85°C - once the driver computed
the motor has cooled to just under 85°C, the TP LED will blink
once and remain on and so will the Fault output signal. To resume
operation, the driver will now need to be disabled and then
Enabled again.
Normal
operation
Warning
zone
Shut down
zone
TP LED
Off
Blinking
On
Fault output (pin #3)
Off
Toggles on/off
On
Motor
Enabled
Enabled
Disabled
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com