ZY04 to 12 Bottom Duct Application (Belt Drive)
Table 42: ZY04 (3.0 Ton) Bottom Duct
1
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
900
n/a
n/a
878
0.26
976
0.37
1070
0.47
1161
0.58
1247
0.67
1329
0.76
1405
0.85
1477
0.93
1543
1.00
1000
792
0.20
894
0.31
992
0.42
1087
0.52
1177
0.62
1263
0.72
1345
0.81
1422
0.90
1493
0.98
1560
1.05
1100
810
0.26
912
0.37
1010
0.47
1104
0.58
1195
0.68
1281
0.77
1363
0.87
1439
0.95
1511
1.03
1577
1.11
1200
829
0.32
931
0.43
1029
0.54
1124
0.64
1214
0.74
1300
0.84
1382
0.93
1459
1.02
1530
1.10
1593
1.17
1300
850
0.39
952
0.50
1050
0.61
1145
0.71
1235
0.81
1321
0.91
1403
1.00
1480
1.09
1552
1.17
--
--
1400
874
0.47
975
0.58
1073
0.69
1168
0.79
1258
0.89
1344
0.99
1426
1.08
1503
1.17
1575
1.25
--
--
1500
899
0.56
1000
0.67
1098
0.77
1193
0.88
1283
0.98
1370
1.07
1451
1.17
1528
1.25
1600
1.33
--
--
Medium Static Option with Motor rated at 2.4-hp
High Static Option with Motor rated at 2.9-hp
--
Exceeds recommended blower speed
1
Blower performance includes gas heat exchangers and 2 in. filters. See STATIC RESISTANCE table for additional applications.
Note:
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = 0.929
x BHP
Table 43: ZY05 (4.0 Ton) Bottom Duct
1
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
1200
840
0.37
929
0.46
1016
0.56
1101
0.68
1184
0.80
1265
0.93
1345
1.04
1423
1.14
1500
1.22
1576
1.28
1300
858
0.43
947
0.52
1035
0.62
1120
0.74
1203
0.86
1284
0.99
1364
1.10
1442
1.20
1519
1.28
1593
1.34
1400
879
0.49
968
0.58
1055
0.69
1140
0.81
1224
0.93
1305
1.05
1385
1.17
1463
1.27
1540
1.35
--
--
1500
903
0.56
992
0.65
1079
0.76
1164
0.88
1247
1.00
1328
1.12
1408
1.24
1486
1.34
1563
1.42
--
--
1600
929
0.64
1018
0.73
1105
0.83
1190
0.95
1273
1.07
1354
1.20
1434
1.31
1512
1.41
1589
1.49
--
---
1700
957
0.72
1047
0.81
1134
0.91
1219
1.03
1302
1.15
1383
1.28
1463
1.39
1541
1.49
--
--
--
--
1800
989
0.80
1078
0.89
1165
1.00
1250
1.12
1333
1.24
1415
1.36
1494
1.47
1572
1.58
--
--
--
--
1900
1023
0.89
1112
0.98
1199
1.08
1284
1.20
1367
1.33
1449
1.45
1528
1.56
--
--
--
--
--
--
2000
1059
0.98
1149
1.07
1236
1.18
1321
1.29
1404
1.42
1485
1.54
1565
1.65
--
--
--
--
--
--
Medium Static Option with Motor rated at 2.4-hp
High Static Option with Motor rated at 2.9-hp
--
Exceeds recommended blower speed
1
Blower performance includes gas heat exchangers and 2 in. filters. See STATIC RESISTANCE table for additional applications.
Note:
See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP. kW = 0.929
x BHP
INSTALLATION MANUAL ZY SERIES 3 - 10 ton 60 Hertz R-410A
91
Johnson Controls Ducted Systems
Содержание ZY Series
Страница 2: ...2 INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Страница 8: ...Nomenclature INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 8 Johnson Controls Ducted Systems ...
Страница 139: ...Start Up Sheet INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 139 Johnson Controls Ducted Systems ...
Страница 140: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 140 Johnson Controls Ducted Systems ...
Страница 141: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 141 Johnson Controls Ducted Systems ...
Страница 142: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 142 Johnson Controls Ducted Systems ...
Страница 143: ...INSTALLATION MANUAL ZY SERIES 3 10 ton 60 Hertz R 410A 143 Johnson Controls Ducted Systems ...