5.1.8.4 Enter emergency operation from timer mode, then timer is cancelled.
5.1.9 Test run:
5.1.9.1 The temperature sensor of inlet air doesn’t work, and compressor starts (but subject to the
limit of -minute delay excluding the first time), and high wind, cooling, and air door is open.The indoor fan
motor runs, running indicator lights up, compressor relay and the one of outdoor fan motor is closed
5.1.9.2 During test run:
The prevention of freezing of evaporator doesn’t work.
Current cross control doesn’t work.
The control of current cross peak expiration doesn’t work.
Temperature control doesn’t work.
Temperature expiration control doesn’t work.
5.1.10 memory function
The memory function of power down is available, and the auto recovery
function of power on is optional. (In auto, heating, cooling, or defrosting status, press the “sleeping”
button 10 times within 5 seconds, and the auto recovery function of power on can be set on/off. If the
buzzer rings 4 times, the the auto recovery function of power on is available; If the buzzer rings 2 times,
the the auto recovery function of power on is unavailable.)
If there is no EEPROM, the unit is taken off the ‘off’ function of the memory function of power down.
But the memory function of power down can also be set on/off, and the data is the default value of chip.
5.1.11 Alarm from indoor fan motor:
2 minutes later after the indoor fan motor is charged, and the
impulse from fan motor is not detected, hen send alarm signals.
5.2 Value of Thermistor
5.2.1 Indoor unit
Room sensor
R25 =23K ±3.5%
B25 /50 =4200K±3%
Temp.( )
Max.(K )
Normal(K )
Min.(K )
Tolerance( )
-30
568.8372
501.0746
440.8435
-1.97
1.75
-29
530.9600
468.6491
413.1441
-1.95
1.74
-28
495.8488
438.5314
387.3645
-1.93
1.72
-27
463.2850
410.5433
363.3602
-1.91
1.71
-26
433.0683
384.5212
340.9980
-1.90
1.70
-25
405.0156
360.3153
320.1558
-1.88
1.69
-24
378.9588
337.7879
300.7211
-1.86
1.67
-23
354.7440
316.8126
282.5905
-1.84
1.66
-22
332.2300
297.2732
265.6686
-1.82
1.64
-21
311.2873
279.0627
249.8676
-1.80
1.63
-20
291.7969
262.0831
235.1067
-1.78
1.62
-19
273.6494
246.2437
221.3111
-1.76
1.60
-18
256.7445
231.4612
208.4122
-1.74
1.59
-17
240.9897
217.6590
196.3462
-1.72
1.57
-16
226.3000
204.7662
185.0545
-1.70
1.56
-15
212.5973
192.7176
174.4829
-1.68
1.54
YSCC/H07/09/12FSAADG
17
Содержание YORK YSCC/H09FSAADG
Страница 37: ...YSCC H07 09 12FSAADG 35 ...
Страница 50: ...8 5 Sound level YSCC H07FSAADG YSCC H07FSAADG pressure M L 36 33 28 48 220V 60HZ YSCC H07 09 12FSAADG 48 ...
Страница 51: ...YSCC H09FSAADG pressure M L 39 34 30 YSCC H09FSAADG 50 220V 60HZ 49 YSCC H07 09 12FSAADG ...
Страница 52: ...YSCC H12FSAADG pressure M L 39 35 31 YSCC H12FSAADG 39 220V 60HZ YSCC H07 09 12FSAADG 50 ...
Страница 57: ...Domestic air conditioner Piping diagrams YSCC H07 09 12FSAADG 55 ...
Страница 61: ...Dimensional drawings 10 4 Dimensional drawings YSCC H07 09FSAADG YSCC H12FSAADG YSCC H07 09 12FSAADG 59 ...
Страница 67: ...The end YSCC H07 09 12FSAADG ...