5.1.6 Timer function:
You can set 24-hour timer on or timer off as required, and the minum time unit is 1 minute. After
setting, the indicator of indoor unit is on , and it is off when timer setting is completed. There are several
timer mode as follows.
5.1.6.1 Timer on: The LED of “timer on” lights up, and unit behaves with halt status. Timer on is
completed, and then unit starts running with the LED of “timer on” off. The unit starts with the the last
setting receiving timer signals, and sleep setting is not allowed.
5.1.6.2 Timer off: Unit starts, timer indicator lights up; When reaching time setting, the indicator
goes out, unit enters shut down mode, and sleep function can be set. If timer off and sleep are set
synchronously, the one which time is short run first. Executing shutdown instruction clear timer and sleep
function.
5.1.6.3 Timer on and timer off can be set synchronously.
5.1.7 Sleep function
: the timer indicator lights up.
5.1.7.1 In cooling/defrosting mode, the temp. setting increases 1
one hour later after start up.
After another hour the temp. setting increase by more 1 and then run continuously for another 6 hours
and then close.
5.1.7.2 In heating mode, the temp. setting decrease 2
one hour after start up. After another
hour the temp. setting decrease by more 2 . After 3 hours the temp. setting rise by 1 and then run
continuously for another 3 hours and then close.
5.1.7.3 If the wind speed is set to high before going to bed, the wind speed become medium after
start up; If the wind speed is set to medium before going to bed, the wind speed become low after start
up; If the wind speed is set to low before going to bed, the wind speed keep unchanged.
5.1.8 Emergency switch imput:
5.1.8.1 Press the switch of emergency operation, then buzzer rings once and unit enters the
automatic operation mode. (emergency operation)
5.1.8.2 If the switch is kept pressed for 5 seconds, buzzer ring two times and unit enter enter test
run mode.
5.1.8.3 Press the switch again, and then closes.
YSCC/H07/09/12FSAADG
16
Содержание YORK YSCC/H09FSAADG
Страница 37: ...YSCC H07 09 12FSAADG 35 ...
Страница 50: ...8 5 Sound level YSCC H07FSAADG YSCC H07FSAADG pressure M L 36 33 28 48 220V 60HZ YSCC H07 09 12FSAADG 48 ...
Страница 51: ...YSCC H09FSAADG pressure M L 39 34 30 YSCC H09FSAADG 50 220V 60HZ 49 YSCC H07 09 12FSAADG ...
Страница 52: ...YSCC H12FSAADG pressure M L 39 35 31 YSCC H12FSAADG 39 220V 60HZ YSCC H07 09 12FSAADG 50 ...
Страница 57: ...Domestic air conditioner Piping diagrams YSCC H07 09 12FSAADG 55 ...
Страница 61: ...Dimensional drawings 10 4 Dimensional drawings YSCC H07 09FSAADG YSCC H12FSAADG YSCC H07 09 12FSAADG 59 ...
Страница 67: ...The end YSCC H07 09 12FSAADG ...