Table 3: Dimensions - XAU uncased upflow or

downflow coil

Dimensions

Height Width

Refrigerant

connections

line size

Models

A (in.) B (in.)

Liquid

(in.)

Vapor

(in.)

XAUA18AXXN1 16 5/8

13

XAUA24BXXN1 18 3/4

13

XAUB30CXXN1 21 1/4

16

XAUB36DXXN1 21 1/2

16

3/4

XAUC42EXXN1

23

19 1/2

XAUC48FXXN1

25

19 1/2

XAUC60GXXN1 29 1/4 19 1/2

XAUD60GXXN1 28 3/4

23

XAUD60HXXN1

33

23

3/8

7/8

Note:

• Refrigerant line sizes may require larger lines

for extended line lengths. Refer to application

data part number 247077.

• The adapter fitting must be field installed for

any refrigeration piping sizes not shown in the

table.

• Refer to the 

Technical Guide

 for the outdoor unit

for the proper refrigeration piping size.

Limitations

Install the coil in accordance with all national and local

safety codes. See Table 4.

Table 4: Coil airflow limits

CFM limits

Coil size

Outdoor

unit (ton)

Minimum

Maximum

18

1 1/2

525

675

1 1/2

525

675

24

2

700

900

2

700

900

30

2 1/2

875

1125

2 1/2

875

1125

36

3

1050

1350

3

1050

1350

42

3 1/2

1225

1575

3

1050

1350

3 1/2

1225

1575

48

4

1400

1800

4

1600

1800

60

5

1750

2250

Installation overview

1.  Before installation, review the installation aids

available in 

Installation verification

. During

installation, use the installation aids to verify that

tasks are completed as required. See Figure 7 for an

overview of components and their location.

2.  Install the coil metering device as required. See

Using a coil metering device

.

3.  Install the coil. See 

Installing the coil: XAF and XAH

coils

 or 

Installing the coil: XAU coils

.

4.  Connect the duct system. See 

Connecting the duct

system

.

5.  Connect the condensate drain lines. See 

Connecting

the condensate drain

.

6.  Connect the refrigerant lines. See 

Connecting

refrigerant lines

.

7.  Clean the coil. See 

Cleaning the coil

.

8.  Check and adjust airflow as required. See 

Adjusting

the air system

.

9.  Instruct the homeowner as needed. See 

Instructing

the homeowner

.

Using a coil metering device

You must install a piston or TXV (flex coil models) in the

field, unless you are using a coil with a factory installed

TXV or a coil equipped with an electronic expansion valve

(EEV). See 

Using a coil equipped with an EEV: XAF and XAH

coils

. Refer to the 

Technical Guide

 for outdoor units for

information on the piston or TXV required for the indoor

coil. It is best practice to install the piston or TXV kit before

installing the coil and brazing the refrigeration piping.

Note: 

Do not install the TXV sensing bulb until you

have completed the brazing and the piping has

cooled.

For TXV installation, refer to the 

Installation Manual

provided with the TXV kit and see 

Installing a TXV

.

For piston installation, see 

Installing a piston

. The piston

and the Schrader valve core are supplied with the outdoor

unit if applicable. Some outdoor sections require a TXV. If

using a piston instead of a TXV, install the Schrader valve

core in the suction line equalizer connection port and cap

the Schrader valve core with the plastic cap supplied. Do

not install the Schrader valve core if a TXV is installed,

because the TXV equalizer line attaches to the equalizer

connection port or suction line port.

 CAUTION

COIL UNDER PRESSURE

Verify that pressure has been released by depressing

Schrader valve core shown in Figure 1 and Figure

2. The coil requires a metering device to be added.

Refer to outdoor unit documentation for correct TXV

or piston to be used.

Installation Manual: XAF, XAH, and XAU Series - Full Cased and Uncased Coils for Cooling and Heat Pumps

12

Johnson Controls Ducted Systems 

Содержание XAF Series

Страница 1: ...ll Cased and Uncased Coils for Cooling and Heat Pumps XAF full cased upflow or downflow XAH full cased horizontal left or right and XAU uncased upflow or downflow York International Corporation 5005 Y...

Страница 2: ...2 Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Cooling and Heat Pumps Johnson Controls Ducted Systems...

Страница 3: ...coils 20 Repositioning the transition angle for downflow or horizontal right application with a furnace XAF and XAH coils 20 Horizontal right and left applications XAH coils 20 Installing the coil XA...

Страница 4: ...4 Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Cooling and Heat Pumps Johnson Controls Ducted Systems...

Страница 5: ...njury or property damage Refer to this manual for assistance For additional information consult a qualified installer or service agency CAUTION This product must be installed in strict compliance with...

Страница 6: ...r Figure 2 Inspect the coil for possible damage during transit If damage is evident note the extent of the damage on the carrier s delivery receipt Make a separate request for inspection by the carrie...

Страница 7: ...AF upflow or downflow full cased coil Figure 4 Dimensions XAF upflow or downflow full cased coil Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Cooling and Heat Pumps 7 Jo...

Страница 8: ...20 20 XAFD42EXXN1 25 24 1 2 23 1 2 23 1 2 XAFD42EBCN1 25 24 1 2 23 1 2 23 1 2 XAFC48FXXN1 27 21 20 20 XAFC48FBAN1 27 21 20 20 XAFC48FBCN1 27 21 20 20 XAFD48FXXN1 27 24 1 2 23 1 2 23 1 2 XAFD48FBAN1 27...

Страница 9: ...l cased horizontal left or right coil Figure 6 Dimensions XAH full cased horizontal left or right coil Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Cooling and Heat Pump...

Страница 10: ...20 XAHC48FBCN1 33 21 20 20 XAHD48FXXN1 32 3 4 24 1 2 23 1 2 23 1 2 XAHD48FBAN1 32 3 4 24 1 2 23 1 2 23 1 2 XAHD48FBCN1 32 3 4 24 1 2 23 1 2 23 1 2 XAHC60GXXN1 37 1 4 21 20 20 XAHC60GBAN1 37 1 4 21 20...

Страница 11: ...AH coils Figure 8 Component location XAU uncased upflow or downflow coil Figure 9 Dimensions XAU uncased upflow or downflow coil Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils...

Страница 12: ...6 Connect the refrigerant lines See Connecting refrigerant lines 7 Clean the coil See Cleaning the coil 8 Check and adjust airflow as required See Adjusting the air system 9 Instruct the homeowner as...

Страница 13: ...if the coil was in the upflow position and adjust as necessary See Figure 10 3 Install the Schrader valve core supplied with the outdoor unit into the equalizer fitting connection port using a valve c...

Страница 14: ...potentially causing leaks 5 Slide the nut removed in Step 3 over the supplied liquid line Place the supplied PTFE washer from the TXV kit in place on the TXV and install the liquid line to the top of...

Страница 15: ...Cover the bulb completely to insulate it Figure 13 TXV bulb and equalizer line installation 9 When the refrigeration piping is installed leak test the system Figure 14 Correct bulb location for TXV In...

Страница 16: ...t the communication 4 wire cable included to the communicating 4 pin connector on the furnace or modular blower control board See Figure 15 and Figure 16 for the connection diagrams and see Figure 17...

Страница 17: ...17 Wiring diagram EEV Figure 18 XAF and XAH coils with an EEV installed Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Cooling and Heat Pumps 17 Johnson Controls Ducted S...

Страница 18: ...ecure the flanges in place using screws as shown in Figure 19 For field installed duct flanges XAH only attach the flanges shipped in the bag with the coil as shown in Figure 20 2 Use the tie plates t...

Страница 19: ...ations with furnaces Figure 23 Vertical upflow applications with modular air handlers Figure 24 Vertical downflow applications with modular air handlers Installation Manual XAF XAH and XAU Series Full...

Страница 20: ...screws that fasten the transition angle to the bottom front side of the cabinet 2 Remove the two screws from the top front side of the cabinet 3 Remove the transition angle rotate the transition angle...

Страница 21: ...o place with two screws as shown in Figure 29 2 Install the horizontal right drain pan extension with four screws as shown in Figure 29 Install the horizontal right drain pan extension onto the coil c...

Страница 22: ...es The following installation steps are provided only for reference for those who want to follow them Experienced sheet metal duct work technicians can choose to follow their own practices provided th...

Страница 23: ...m at a 90 angle See Figure 33 Table 7 Duct work dimensions in XAU coils Cabinet width Cabinet height Coil shelf opening width pre form Panel height Duct connector lower Duct connector upper Opening wi...

Страница 24: ...n in Figure 34 Figure 34 Coil shelf 7 Install the coil shelf through the plenum opening so that the duct flanges on the furnace support the coil shelf See Figure 35 Install the coil shelf level or pit...

Страница 25: ...anel installation See Figure 36 and Table 7 for the designated sizes Install standard S Locks onto the sides and top edges of the plenum access opening 12 Install the coil access panel onto the plenum...

Страница 26: ...ited to the installation You can use upflow horizontal or downflow applications Adhere to the following The vast majority of problems encountered with heating and cooling systems can be linked to inco...

Страница 27: ...uilding codes Install the coil level or pitched slightly toward the drain end Suggested pitch must not exceed 1 4 in ft of coil Note that you can remove drain plugs using a standard 3 8 in drive socke...

Страница 28: ...iers Important For EEV equipped coils only The EEV in this unit is shipped in the closed position to protect the valve during transportation Before brazing do the following i Connect the communication...

Страница 29: ...r to the furnace or modular air handler instructions for more information To check the CFM you measure the static pressure drop across the coil using a portable manometer and static pressure tips The...

Страница 30: ...a n a n a XAFC42E 0 02 0 04 0 08 0 11 0 16 0 21 0 27 n a n a XAFD42E 0 02 0 05 0 07 0 10 0 13 0 17 0 21 n a n a XAFC48F 0 01 0 04 0 07 0 10 0 14 0 19 0 24 0 30 n a XAFD48F 0 02 0 04 0 06 0 08 0 11 0...

Страница 31: ...16 0 21 0 27 0 33 XAFD60J 0 02 0 04 0 07 0 11 0 16 0 22 0 28 0 34 0 42 Note Airflow data is for dry coil conditions only tested without filters For optimal performance external static pressures of 0...

Страница 32: ...16 0 23 0 30 n a n a n a XAHC42E 0 03 0 07 0 11 0 15 0 21 0 28 0 37 n a n a XAHD42E 0 03 0 06 0 09 0 13 0 17 0 22 0 29 n a n a XAHC48F 0 03 0 06 0 10 0 14 0 20 0 26 0 34 0 43 n a XAHD48F 0 00 0 04 0 0...

Страница 33: ...low data is for dry coil conditions only tested without filters For optimal performance external static pressures of 0 2 in W C to 0 6 in W C are recommended Applications above 0 6 in W C are not reco...

Страница 34: ...plugged drain connections XAU Figure 41 Location of coil trapped and plugged drain connections with furnace XAF and XAH Installation Manual XAF XAH and XAU Series Full Cased and Uncased Coils for Coo...

Страница 35: ...of coil trapped and plugged drain connections with modular air handler XAF and XAH Note Verify that all drains are tapped or plugged Installation Manual XAF XAH and XAU Series Full Cased and Uncased...

Страница 36: ...ess door Third Party Trademarks Notice For information about third party trademarks refer to the relevant company websites Subject to change without notice Published in U S A Copyright 2021 by Johnson...