VA9905 Actuator Technical Specifications 

Product description

VA9905-KGA-1: 

Proportional mode, 

VA9905-KGA-2: 

Proportional mode

Power requirements

AC 24 V ±20% at 50/60 Hz, Class 2 (North America) or SELV (Europe), 5.2 VA Running; 

DC 24 V ±10%  Class 2 (North America) or SELV (Europe), 1.1 W Running.

Transformer sizing 

requirements

≥6 VA

Input signal/adjustments

0 (2) to 10 VDC or 0 (4) to 20 mA with field  furnished 500 ohm 1/4 W resistor

Control impedance

100k ohm

Rotation rate

1.5 ° per second

Cycles

60,000 full stroke cycles; 2,500,000 repositions 

Audible noise

<35 dBA at 1 m (39-13/32 in.)

Electrical connections

-1 halogen-free

1.2 m (48 in.) halogen free cable with 

0.82 mm² (18 AWG) conductors and  

 6 mm (0.25 in.) ferrule ends

-2 plenum-rated

3.05 m (120 in.) UL 444 type CMP plenum 

rated cable with 0.75 mm² (19 AWG cable) 

conductors and 6 mm (0.25 in.) ferrule ends

Conduit connections

13 mm NPSM (1/2 in.) threaded conduit connectors with M9300-100 conduit

Ambient conditions

Operating: 

0 to 60°C (32 to 140°F), 90% RH, noncondensing

Storage: 

-

40 to 85°C (

-

40 to 185°F), 95% RH, noncondensing

Enclosure

IP54/NEMA 5

Dimensions

VA9905 Actuator: 

Width: 89 mm (3-1/2 in.), Height: 74 mm (2-15/16 in.), Length: 170 

mm (5-11/16 in.) 

Shipping weight 

Valves:

• 

VG1611AF: 0.7 Kg (1.55 lbs)

• 

VG1641AF: 0.8 Kg (1.85 lbs)

• 

VG1671AF: 1 Kg (2.20 lbs)

Actuator

• 

VA9905: 0.8 Kg (1.75 lbs)

Compliance

United States:

 UL Listed, CCN XAPX, File E27734; to UL 60730-1: Automatic Electrical 

Controls for  Household and Similar Use, Part 1; and UL 60730-2-14: Part 2, Particular 

Requirements  for Electric Actuators. Plenum Rated (UL 2043). Suitable for use in Other 

Environmental  Air Space (Plenum) in accordance with section 300.22 (c) of the National 

Electrical Code.

Canada:

 UL Listed, CCN XAPX7, File E27734; to CAN/CSA E60730-1:02: Automatic 

Electrical  Controls for Household and Similar Use, Part 1; and CAN/CSA-E60730-2-14, 

Particular  Requirements for Electric Actuators.

Europe:

CE Mark—Johnson Controls declares that this product is in compliance with the 

essential requirements and other relevant provisions of the EMC Directive.

IEC 60730-1: Automatic Electrical Controls for Household and Similar Use, Part 1: 

General Requirements and IEC 60730-2-14, Automatic Electrical Controls for Household 

and Similar Use; Part 2—Particular Requirements for Electric Actuators

Australia and New Zealand: 

RCM—Australia/NZ Emissions Compliant

The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond 

these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from 

misapplication or misuse of its products.

8

Содержание VA9905 Series

Страница 1: ...14 88360 03206 Rev VA9905 Actuator and VG1600 Series Six Way Valves Installation Instructions...

Страница 2: ...s ou d endommager l quipement contr l ou un autre quipement la conception du syst me de contr le doit int grer des dispositifs de protection suppl mentaires Veiller dans ce cas int grer de fa on perma...

Страница 3: ...14 88360 03206 Rev A Parts Included Tools Required 8mm 5 16 in slotted screwdriver or a TORX T 20 driver Two Flow Disk Sets VA9905 Actuator VG1600 Series Valve Two Ring Nuts 2...

Страница 4: ...ed disks with hot water only Flow restriction disks have markings that indicate the rate of restriction they provide Using the supplied restriction disks you can set the following flow rates in ports...

Страница 5: ...Source 2 return Controlled by the orange wire The diagram below illustrates the input and output flows for the 6 way valve Use this diagram as a guide on how to install the 6 way valve to your system...

Страница 6: ...override button on the actuator AC 24 V DC 0 2 10V BLK RED GRY ORN 1 2 3 4 Move the actuator lever to the extreme right position 3 Align the top of the 6 way valve to the plate at the back of the actu...

Страница 7: ...dip switch 1 to the ON position or 0 to 10 V Push dip switch 1 to the OFF position Wiring the Actuator Wire Color Input Black Com 24 V AC DC Red Gray Source 1 control Y1 DC 0 2 10 V Orange Source 2 co...

Страница 8: ...ctuator to a Six way Valve section sets ports 1 and 4 to full flow Note The ball valve and actuator pointer rotate in opposite directions The following illustrations indicate lever position and flow F...

Страница 9: ...11AF 0 7 Kg 1 55 lbs VG1641AF 0 8 Kg 1 85 lbs VG1671AF 1 Kg 2 20 lbs Actuator VA9905 0 8 Kg 1 75 lbs Compliance United States UL Listed CCN XAPX File E27734 to UL 60730 1 Automatic Electrical Controls...

Страница 10: ...alve Body with Male BSPP Thread external Valve Body with Female NPT Thread internal Sweat Union Fitting kit Flow coefficient Flow control disk Leakage rate A 100 000 cycles in iron oxide contaminated...

Отзывы: