RAPID RESPONSE Series LFII Residential 

4.9 K-factor Concealed Pendent Sprinkler 

Flat Plate, Wet Pipe and Dry Pipe Systems

Page 1 of 6 

APRIL 2019 

TFP442

IMPORTANT

Refer to Technical Data Sheet 

TFP2300 for warnings pertaining to 

regulatory and health information.
Always refer to Technical Data 

Sheet TFP700 for the “INSTALLER  

WARNING” that provides cautions 

with respect to handling and instal-

lation of sprinkler systems and com-

ponents. Improper handling and 

installation can permanently damage 

a sprinkler system or its compo-

nents and cause the sprinkler to fail  

to operate in a fire situation or cause  

it to operate prematurely.

Worldwide 

Contacts

www.tyco-fire.com

General 

Description

The TYCO RAPID RESPONSE

 

Series 

LFII Residential 4.9K Concealed 

Pendent Sprinklers (TY3596) are dec-

orative, fusible solder sprinklers, avail-

able in both ordinary 160

°

F (71

°

C) and 

intermediate 212

°

F (100

°

C) tempera-

ture rated configurations. They are 

designed for use in residential occu-

pancies such as homes, apartments, 

dormitories, and hotels.
The cover plate assembly conceals 

the sprinkler operating components 

above the ceiling. The flat profile of the 

cover plate provides the optimum aes-

thetically appealing sprinkler design. 

In addition, the concealed design 

of the Series LFII Residential Con-

cealed Pendent Sprinklers provides 

1/2 in. (12,7 mm) vertical adjustment. 

This adjustment provides a measure 

of flexibility when cutting fixed sprin-

kler drops.
The Series LFII Residential Concealed 

Pendent Sprinklers are intended for use 

in the following scenarios:
•  Wet and dry pipe residential sprin-

kler systems for one and two fam-

ily dwellings and mobile homes per 

NFPA 13D

•  Wet and dry pipe residential sprin-

kler systems for residential occupan-

cies up to and including four stories 

in height per NFPA 13R

•  Wet and dry pipe sprinkler systems 

for the residential portions of any 

occupancy per NFPA 13

The Series LFII Residential Concealed 

Pendent Sprinklers have been designed 

with heat sensitivity and water distri-

bution characteristics proven to help 

in the control of residential fires and to 

improve the chance for occupants to 

escape or be evacuated.
The Series LFII Residential Con-

cealed Pendent Sprinklers (TY3596) 

are shipped with a Disposable Protec-

tive Cap. The Protective Cap is tem-

porarily removed for installation, and 

then it can be replaced to help protect 

the sprinkler while the ceiling is being 

installed or finished. The tip of the Pro-

tective Cap can also be used to mark 

the center of the ceiling hole into the 

plaster board, ceiling tiles, and so on, 

by gently pushing the ceiling product 

against the Protective Cap. When the 

ceiling installation is complete the Pro-

tective Cap is removed and the Cover 

Plate Assembly is installed.

Dry Pipe System Application

The 160

°

F (71

°

C) temperature rated 

Series LFII Residential Concealed 

Pendent Sprinklers offer a laboratory 

approved option for designing dry pipe 

residential sprinkler systems, whereas, 

most residential sprinklers are labora-

tory approved for wet systems only.
Through extensive testing, it has 

been determined that the number of 

design sprinklers (hydraulic design 

area) for the Series LFII Residential 

Concealed Pendent Sprinklers need 

not be increased over the number of 

design sprinklers (hydraulic design 

area) as specified for wet pipe sprinkler 

systems, as is accustomed for density/

area sprinkler systems designed per 

NFPA 13.

Consequently, the Series LFII Residen-

tial Concealed Pendent Sprinklers offer 

the features of non-water filled pipe in 

addition to not having to increase the 

number of design sprinklers (hydraulic 

design area) for systems designed to 

NFPA 13, 13D, or 13R.

NOTICE

The Series LFII Residential Concealed 

Pendent Sprinklers (TY3596) described 

herein must be installed and main-

tained in compliance with this docu-

ment and with the applicable standards 

of the NATIONAL FIRE PROTECTION 

ASSOCIATION (NFPA), in addition to 

the standards of any authorities having 

jurisdiction. Failure to do so may impair 

the performance of these devices.
The owner is responsible for main-

taining their fire protection system 

and devices in proper operating con-

dition. Contact the installing contrac-

tor or product manufacturer with any 

questions.