TFP223

Page 5 of 6

Limited 

Warranty

For warranty terms and conditions, visit 

www.tyco-fire.com.

Ordering 

Procedure

Contact your local distributor for avail-

ability. When placing an order, indicate 

the full product name and Part Number 

(P/N).

Sprinkler Assemblies with NPT 

Thread Connections

Specify: Series EC-8 (TY4232), K=8.0, 

Extended Coverage (Light Hazard) 

Pendent Sprinkler, (specify) tem-

perature rating, (specify) finish, P/N 

(specify):

135°F (57°C)

Natural Brass . . . . . . . . . . . . . PSN 50-801-1-135

Signal White (RAL9003) 

Polyester  . . . . . . . . . . . . . . . .PSN 50-801-4-135

Chrome Plated . . . . . . . . . . . .PSN 50-801-9-135

155°F (68°C)

Natural Brass . . . . . . . . . . . . . PSN 50-801-1-155

Signal White (RAL9003) 

Polyester  . . . . . . . . . . . . . . . .PSN 50-801-4-155

Chrome Plated . . . . . . . . . . . .PSN 50-801-9-155

Recessed Escutcheon

Specify: Style (30 or 40) Recessed 

Escutcheon with (specify*) finish, P/N 

(specify*)

*Refer to Technical Data Sheet TFP770

Sprinkler Wrench

Specify: W-Type 3 Sprinkler Wrench, 

P/N 56-895-1-001
Specify: W-Type 23 Recessed Sprinkler 

Wrench, P/N 56-000-6-838

Содержание tyco EC-8 Series

Страница 1: ...ush pendent position whereas the Style 40 provides 3 4 in 19 1 mm of verti cal adjustment from the flush pendent position The adjustment provided by the Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut Corrosion resistant coatings where applicable are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obt...

Страница 2: ...ded Coverage Sprinklers are to be installed in accor dance with the applicable Factory Mutual Loss Prevention Data Sheet Information provided in the FM Loss Prevention Data Sheet relate to but are not limited to hydraulic design ceiling slope and obstructions minimum and maximum allowable spacing and deflector to ceiling distance HAZARD TYPE TEMP BULB LIQUID SPRINKLER FINISH See Note 4 NATURAL BRA...

Страница 3: ...hten pendent sprin klers using only the W Type 3 End A Sprinkler Wrench Wrench tighten the recessed pendent sprinklers using only the W Type 23 Sprinkler Wrench The wrench recess of the applicable sprin kler wrench Ref Figures 4 and 5 is to be applied to the sprinkler wrench flats Ref Figure 1 Area Style 135 F 57 C 155 F 68 C 16 x 16 Pendent QR QR 16 x 16 Style 30 Recessed QR QR 16 x 16 Style 40 R...

Страница 4: ...ffice however instead of inspecting from the floor level a random sampling of close up visual inspections should be made so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating as it may be affected by the corrosive conditions present The owner is responsible for the inspection testing and maintenance of their fire protection system an...

Страница 5: ...kler specify tem perature rating specify finish P N specify 135 F 57 C Natural Brass PSN 50 801 1 135 Signal White RAL9003 Polyester PSN 50 801 4 135 Chrome Plated PSN 50 801 9 135 155 F 68 C Natural Brass PSN 50 801 1 155 Signal White RAL9003 Polyester PSN 50 801 4 155 Chrome Plated PSN 50 801 9 155 Recessed Escutcheon Specify Style 30 or 40 Recessed Escutcheon with specify finish P N specify Ref...

Страница 6: ...re Protection Association TEFLON is a registered trademark of DuPont 1400 Pennbrook Parkway Lansdale PA 19446 Telephone 1 215 362 0700 2018 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice ...

Отзывы: