![Johnson Controls PREMIUM EFFICIENCY VPCS Series Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/johnson-controls/premium-efficiency-vpcs-series/premium-efficiency-vpcs-series_installation-operation-and-maintenance-manual_2024188004.webp)
4
FORM 145.18-IOM2
ISSUE DATE: 06/17/2020
CABINET NOMENCLATURE
1, 2, 3
4, 5
6
7
8
9 10 11 12, 13 14 15 16
VPB 12 M 1 D E A 2 2T 4 0 C
RISER ARRANGEMENT
1 = Right Hand Risers
2 = Left Hand Risers
3 = Back Risers
4 = Right Hand Risers with Cover
5 = Left Hand Risers with Cover
6 = Back Risers with Cover
BLOWER OPTIONS
E = ECM Blower
F = Hi-Static ECM Blower
G = ECM with Continuous Low Speed
H = Hi-Static ECM with Continuous Low Speed
DESIGN SERIES
A = Current Generation
UNIT CAPACITY
09 = 0.75 TON
24 = 2 TON
12 = 1 TON
30 = 2.5 TON
15 = 1.25 TON
36 = 3 TON
18 = 1.5 TON
VOLTAGE
1 = 208/230-60-1
CABINET OPTIONS
Cabinet Height
No OA
Options
Left Top OA Entry
(4-inch Round)
Left Top OA Entry (4-inch
Round with Motorized Damper)
Right Top OA Entry
(4-inch Round)
Right Top OA Entry (4-inch
Round with Motorized Damper)
88 inches
A
G
L
R
W
80 inches
B
H
M
T
X
88 inches with 2-inch Stand
C
J
N
U
Y
80 inches with 2-inch Stand
E
1
3
5
7
80 inches with 4-inch Stand
D
K
P
V
Z
80 inches with 8-inch Stand
F
2
4
6
8
SUPPLY AIR CONFIGURATION
1H = Single Horizontal Supply
2T = Double Horizontal Supply
+ Top
2H = Double Horizontal Supply
3H = Triple Horizontal Supply
3T = Triple Horizontal Supply
+ Top
0T = Top Only
1T = Single Horizontal Supply
+ Top
00 = Field Cut (No Openings)
HORIZONTAL DISCHARGE OPENING
ORIENTATION
00, 0T
1H, 1T
2H, 2T
3H, 3T
X = None B = Back 1 = Left + Front
7 = Front + Left + Right
F = Front 2 = Left + Back
8 = Front + Right + Back
L = Left
3 = Left + Right
9 = Front + Left + Back
R = Right 4 = Right + Back
5 = Right + Front
6 = Back + Front
ELECTRICAL CONNEC-
TION
0 = None (Terminal Block)
D = Non-Fused Disconnect
F = Disconnect with Fuses
MISCELLANEOUS OPTIONS
Filters: MERV (Depth)
Option
4 (1")
8 (1")
13 (2")
Galvanized Drain Pan (DP)
0
F
G
Stainless Steel (SST) Drain Pan
S
T
U
Sealed Openings
L
M
N
SST DP with Sealed
C
D
E
PRODUCT CATEGORY
VPB = Vertical Stacked Heat Pump -
Standard Cabinet Assembly
VPM = Vertical Stacked Heat Pump -
Master Cabinet Assembly
VPS = Vertical Stacked Heat Pump -
Satellite Cabinet Assembly
CONTROL OPTIONS
Thermostat Location
Remote Whip Surface ADA Door
2-Speed Unit-
Mounted Switch
M
W
P
A
3-Speed Ther-
mostat Control
3
4
5
7
Содержание PREMIUM EFFICIENCY VPCS Series
Страница 38: ...38 FORM 145 18 IOM2 ISSUE DATE 06 17 2020 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...46 FORM 145 18 IOM2 ISSUE DATE 06 17 2020 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 48: ...48 FORM 145 18 IOM2 ISSUE DATE 06 17 2020 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 50: ...50 FORM 145 18 IOM2 ISSUE DATE 06 17 2020 Appendix Figure 32 EC MOTOR ECM 3 SPEED FAN WIRING DIAGRAM LD28382...