4. Repeat the test if necessary.
Important:
Room acoustics can artificially extend the range of a glass-break sensor. The specified
range of the PGP922 has been established for worst-case conditions. While the sensor is
likely to function at an additional range, it may miss a minimum output break, or room
acoustics may be changed at some future time, restoring sensor coverage back to the
normal range of 6 m (20 ft).
Do not exceed the rated range of the sensor, regardless of what the tester shows.
LED Indications and Events
Table 4: LED indications and events
LED Response
Description
Red LED blinks
Stabilization (warm-up 8 sec)
Red LED ON 0.2 sec.
Tamper open / close
Red LED ON 2 sec.
Glass break alarm
Green LED ON 2 sec.
Low frequency detection – Test mode
Green and red LED blink alternately
(0.2 sec Green, 0.2 sec Red, 0.4 sec OFF)
Self-test failure – Test mode
Green and red LED blink alternately slowly
(0.2 sec Green, 0.2 sec Red, 30 sec OFF)
Self-test failure – Normal mode
Specifications
Frequency Band
912 to 919 MHz
Modulation
GFSK
Communication Protocol
PowerG
Battery Type
3 V Lithium CR123A GP or Panasonic only
Battery Life
5 years with typical use at room temperature 25°C (77°F)
Note:
Not evaluated by UL/ULC.
Low Battery Threshold
2.6 V
Nominal Operating Voltage
3 V
Operating Temperature
-10°C (14°F) to 50°C (120°F) indoors
Note:
UL/ULC only evaluated 0°C-49°C
Storage Temperature
-20°C (-4°F) to 60°C (140°F)
Relative Humidity
Up to 95% non-condensing
Dimensions (LxWxD)
107.5 x 69 x 30 mm (4.2 x 2.7 x 1.2 in.)
Weight (including battery)
105 g (3.7 oz)
Color
White
Maximum Detection Range
7.6 m (25 ft) if glass size is minimum 40 x 40 cm (15 ¾ in. x 15
¾ in.) 6 m (20 ft) if glass size is 30 x 30 cm (12 in. x 12 in.) to
40 x 40 cm (15 ¾ in. x 15 ¾ in.) For UL/ULC maximum verified
range is 6 m (20ft)
PGP922 Glass Break Detector Installation Guide
10
D-308652 PGP922 Rev.0