UL/ULC notes

Only model PGP9922 operating in the frequency band 912-919MHz is UL/ULC listed. The PGP9922

has been listed by UL/ULC for commercial and residential burglary applications in accordance

with the requirements in the Standards UL 634 and ULC/ORD-C634 for contacts and switches. For

UL/ULC installations use this device only in conjunction with compatible DSC wireless receivers:

HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P) 9, HS2LCDRFPRO9, PG9920, and Qolsys IQPanel2, IQHub,

IQPanel4. After installation, verify the product functionality in conjunction with the compatible

receiver used.

Safety Instructions

Read the safety information before you install the equipment.
The detector shall be installed and used within an environment that provides the pollution degree

max 2 and over voltages category II in non-hazardous locations, indoor only. The equipment is

designed to be installed by SERVICE PERSONS only; (SERVICE PERSON is defined as a person having

the appropriate technical training and experience necessary to be aware of hazards to which that

person may be exposed in performing a task and of measures to minimize the risks to that person

or other persons).

W.E.E.E Product recycling declaration

For information regarding the recycling of this product you must contact the

company from which you originally purchased it. If you are discarding this

product and not returning it for repair then you must ensure that it is returned

as identified by your supplier. This product is not to be thrown away with

everyday waste.

Directive 2012/19/EU Waste Electrical and Electronic Equipment.

About PGP922

The PGP922 is a wireless PowerG two-way acoustic glass-break detector designed to detect the

breaking of framed glass mounted in an outside wall. This device is wall or ceiling mountable

and suitable for most types of window or door glass, including the following: plate, tempered,

laminated, wired, coated, and sealed insulating glass.
The device has the following features:

The device is fully pre-calibrated

Provides temperature and light level reports for PowerG control panels that support this

feature

Alarm and other data are forwarded to the control panel

Back-tamper protection

Periodic supervision message is transmitted automatically to the control panel at regular

interval

A bicolor LED lights whenever events are reported

Remote firmware upgrade

Limited Warranty

Digital Security Controls warrants that for a period of 12 months from the date of purchase, the

product shall be free of defects in materials and workmanship under normal use and that in

fulfilment of any breach of such warranty, Digital Security Controls shall, at its option, repair or

replace the defective equipment upon return of the equipment to its repair depot. This warranty

applies only to defects in parts and workmanship and not to damage incurred in shipping or

13

PGP922 Glass Break Detector Installation Guide

D-308652 PGP922 Rev.0

Содержание PGP922

Страница 1: ...nd ISED Canada RF exposure compliance requirements locate the device at a distance of at least 20 cm from all persons during normal operation Do not co locate the antennas used for this product or operate them in conjunction with any other antenna or transmitter Install the PGP9922 in accordance with the Standard for Installation and Classification of Residential Burglar Alarm Systems UL 1641 and ...

Страница 2: ...enever the door and window contacts are armed Do not use where white noise such as air compressor noise is present A blast of compressed air may cause a false alarm Avoid rooms smaller than 3 x 3 m 10 x 10 ft and rooms with multiple noise sources such as small kitchens glass booths noisy areas garages and small bathrooms Do not install in humid rooms The PGP922 is not hermetically sealed Excess mo...

Страница 3: ...tection is partially dependent on sound reflection off the opposite wall Enrolling the device 1 Refer to the compatible control panel or receiver combination installation manual for the complete set of enrollment instructions and testing procedures 2 From the Installation menu enter the Device enrollment menu and select the option to add a new device 3 Remove the battery pull tab to power on the d...

Страница 4: ...e threshold value for at least the Alert Delay duration Alert restore occurs when the temperature rises 1 C 1 8 F above the threshold for at least the Restore Delay duration Note The default threshold value for cold is 19 C 66 F Optional settings See Configuring the Temperature Alerts FREEZING 7 C 45 F Define whether or not the control panel will report a freezer alert when the temperature drops b...

Страница 5: ...fault The alert delay time values are Immediately 1 min 2 min 10 min default 15 min 20 min 30 min Restore delay Define the amount of time the panel waits before an alert is reported when the temperature exceeds the defined default The restore delay time values are Immediately 1 min 2 min 10 min default 15 min 20 min 30 min Mounting the device using tape 1 Peel the release liners off the two strips...

Страница 6: ...coated and sealed insulating glass The coverage range also depends on the angle between the detector and the glass For a higher angle the maximum range is reduced See the following table and figure for details Angle 0 30 45 60 75 90 Maximum range 7 6 m 25 ft 7 m 23 ft 5 5 m 18 ft 4 m 13ft 2 5 m 8 ft 0 m 0 ft Figure 4 Angle between device and window Callout Description A Device B Window PGP922 Glas...

Страница 7: ...is forcibly removed from the wall this segment will break away from the base causing the tamper switch to open Note Back tamper protection is required for UL commercial burglary installations Figure 5 Device screw installation Callout Description A Screwing device base B Break away segment C Up arrow 3 Clip the cover on the device base and tighten the cover screw See the following figure Figure 6 ...

Страница 8: ...ly enters Test Mode for 15 minutes To manually enter the devices into Test Mode refer to the Control Panel Installer Guide 1 Before you start the test remove the device cover from the base 2 Close the cover to return the tamper switch to its normal position 3 After 10 seconds the LED blinks three times The following table indicates received signal strength indication Table 3 Signal strength indica...

Страница 9: ...e not to shatter the glass during testing To test complete the following steps 1 Switch the device to Test Mode 2 Generate a flex signal and simulate a glass breaking sound by using one of the following methods Simulator in manual mode Hold the simulator close to the protected glass Thump the glass and immediately start the simulator manually to create the sound of breaking glass Examples of such ...

Страница 10: ...4 sec OFF Self test failure Test mode Green and red LED blink alternately slowly 0 2 sec Green 0 2 sec Red 30 sec OFF Self test failure Normal mode Specifications Frequency Band 912 to 919 MHz Modulation GFSK Communication Protocol PowerG Battery Type 3 V Lithium CR123A GP or Panasonic only Battery Life 5 years with typical use at room temperature 25 C 77 F Note Not evaluated by UL ULC Low Battery...

Страница 11: ...m 1 8 in to in Wired 6 4 mm in Coated 3 2 to 6 4 mm 1 8 in to in Laminated 6 4 mm in Sealed Insulating 3 2 to 6 4 mm 1 8 in to in Note Laminated and Sealed Insulating glass types are protected only if both plates of the unit are broken Room Size Not larger than 12 x 12 m 40 x 40 ft Not smaller than 3 x 3 m 10 x 10 ft Min Distance from Glass 1 5 m 5 ft 11 PGP922 Glass Break Detector Installation Gu...

Страница 12: ...ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio...

Страница 13: ...t and not returning it for repair then you must ensure that it is returned as identified by your supplier This product is not to be thrown away with everyday waste Directive 2012 19 EU Waste Electrical and Electronic Equipment About PGP922 The PGP922 is a wireless PowerG two way acoustic glass break detector designed to detect the breaking of framed glass mounted in an outside wall This device is ...

Страница 14: ...ducts or components HARDWARE which You acquired If the DSC software product SOFTWARE PRODUCT or SOFTWARE is intended to be accompanied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy or install the SOFTWARE PRODUCT The SOFTWARE PRODUCT includes computer software and may include associated media printed materials and online or electronic documentation Any software provided a...

Страница 15: ... comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts g Trademarks This EULA does not grant You any rights in connection with any trademarks or service marks of DSC or its suppliers 3 COPYRIGHT All title and intellectual property rights in and to the SOFTWARE PRODUCT including but not limited to any image...

Страница 16: ...NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRANTY NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT e EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WA...

Отзывы: