Product/Technical Bulletin

RLD-H10P

Issue Date

0396

© 1996 Johnson Controls, Inc.

1

Part No. 24-7929-12, Rev. A
Code No. LIT-125604

The RLD-H10P is a professional grade leak detector
for use by refrigeration and air conditioning
technicians.  This detector senses all CFC, HCFC, and
HFC refrigerants and blends, such as R12, R502, R22,
R404a, R507, and R134a among others.  The
RLD-H10P is self-powered with a rechargeable
battery.  A full line of accessories and maintenance kits
is also available, including replacement sensors,
tune-up kits, probe extensions, battery chargers, and
leak vial bottles.

Figure 1:  RLD-H10P Leak Detector

RLD-H10P Refrigerant Leak Detector

Features and Benefits

Positive Ion Emission
Heated Diode Sensor

Provides the most sensitivity available today, while
still detecting all halogenated refrigerant gases

Rechargeable Battery

Enhances portability--no external power required

High Quality Air Pump

Supplies constant air flow to sensor so it responds
quickly to leaks; also helps sensor recover quickly
after exposure to refrigerant so leak can be verified

Auto Balance Circuit

Compensates for background refrigerant levels

Visual and Audible Signal

Facilitates sensing in noisy equipment rooms with
360

°

 visibility and piercing tone;

Frequency of noise/light indicates magnitude of leak

Exceeds SAE J1627
Moving Probe Specification

Minimizes call-backs because the leak is found the
first time, is verifiable, and the fix can be confirmed

External Calibration Source

Indicates when the sensor is working properly and
serves as a reference point to judge leak size

Содержание PENN RLD-H10P

Страница 1: ... Ion Emission Heated Diode Sensor Provides the most sensitivity available today while still detecting all halogenated refrigerant gases Rechargeable Battery Enhances portability no external power required High Quality Air Pump Supplies constant air flow to sensor so it responds quickly to leaks also helps sensor recover quickly after exposure to refrigerant so leak can be verified Auto Balance Cir...

Страница 2: ...s The alkali metals act as the cathode of a diode and the anode is heated by a DC voltage Air from the area being leak checked is pumped from the probe and into the space between the cathode and anode If halogen gas is present it creates an ionized current between the cathode and the anode which is amplified to sound a speaker and light a neon lamp in the probe Sensitivity can be controlled by adj...

Страница 3: ...H10P and to assist in determining the size of the leak When using the small leak range position a leak of HFC causing an audible signal equal to that produced by the leak vial has a leak rate of approximately one half ounce year When using the medium leak range position on a CFC or HCFC system this leak rate would also be approximately one half ounce year Proper response during the calibration tes...

Страница 4: ... inches per second along seams or joints suspected of leaking Start leak checking anywhere and continue in a logical progression through the entire system to locate all leaks Set the range switch to the appropriate range to ensure maximum sensor life If the leak size is unknown start at the Sensor Saver setting IMPORTANT Exposing the sensor to large amounts of refrigerant or holding the probe over...

Страница 5: ...ve the old airflow indicator ball 3 Insert the new airflow indicator ball into the probe 4 Reattach the probe end to the hose Figure 9 Replacing the Filter and Airflow Indicator Replacing the Sensor The sensor is a plug in unit that is thrown away when expended It needs replacement when the RLD H10P no longer responds to the leak vial even with the sensor heat control turned fully clockwise Make s...

Страница 6: ... the filter RLD H10 602R Heat control set too low Increase the sensor heat slightly by turning the sensor heat control knob 1 16th of a turn clockwise See Figure 8 Allow a minute for the sensor to heat then recheck Audio normal lamp does not flash Burned out or damaged probe lamp Return unit to your Johnson Controls PENN representative Responds continuously in Filter is clogged Replace the filter ...

Страница 7: ...icator balls and 3 probe tips RLD H10 603R Replacement leak vial contains enough refrigerant to last approximately six months Repair Information Should it become necessary to repair your RLD H10P please contact your Johnson Controls PENN representative Warranty Repairs Units under warranty will be shipped to Johnson Controls PENN for repairs The repairs will be completed within 24 hours after rece...

Страница 8: ... Time Approximately 2 minutes Accuracy Meets SAE J1627 test requirements Probe Length Approximately 4 5 ft 1 4 m Ambient Operating Conditions 32 to 104 F 0 to 40 C 5 90 RH non condensing Ambient Storage Conditions 14 to 140 F 10 to 60 C 5 90 RH non condensing Case Rugged high density polyethylene Dimensions H x W x D 5 5 x 10 5 x 8 5 in 140 x 267 x 216 mm Shipping Weight 5 lb 2 3 kg Agency Listing...

Отзывы: