Sending the unique identifier (UID)
Figure 22: UID terminal block shorting diagram
If RS-485 communication is not detected when you turn on the reader, configure the reader to send
the UID with supported 13.56 credentials.
To configure the reader to send the UID, complete the following steps:
1. Short circuit together the D0 and LED terminals.
2. Apply power to the reader.
A simultaneous sequence of five beeps and flashes, four times, indicates a successful
configuration to the UID option.
A sequence of rapid beeps and flashes for 4 seconds indicates that the device is not configured
to the UID format.
ioSmart Card Reader Installation Guide