501562-UIM-A-0909
Johnson Controls Unitary Products
9
FIGURE 11:
Thermostat Chart - Two Stage AC – Two Stage Variable Speed Furnaces
AC 24B
Two
Stage Air Conditioner – Two Stage Variable Speed Furnace
Connection of the “C”
Terminal, 24-Volt Common,
is optional when used with
batteries
Part Numbers:
SAP = Legacy
265904 = 031-09169
1
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
TWO STAGE
VARIABLE SPEED
FURNACE CONTROL
G
Fan
TWO STAGE
VARIABLE SPEED
FURNACE
W/W1
First Stage Heat
Y/Y2
Second or Full
Stage Compressor
W2
Second Stage Heat
O
Reversing Valve
X/L
Malfunction Light
DHUM
Dehumidification
1
Move DHUM
jumper to “YES”
if humidistat is to be used.
(G/L)*(8/9)V
(F/L)*(8/9)V
PV(8/9)
ID MODELS
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
External Humidistat
(Optional)
Open on Humidity Rise
24VAC Humidifier
(Optional)
External Humidistat
(Optional)
Open on Humidity Rise
2
2
Part Number:
S1-2HU16700124
2
C
24 – Volt Common
R
24 – Volt Hot
Y
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
*DN22C00124
THERMOSTAT
W2
Second Stage Heat
C
24 – Volt Common
R
24 – Volt Hot
Y1
First Stage Compressor
Y2
Second Stage
Compressor
G
Fan
*DP22U70124
THERMOSTAT
W2
Second Stage Heat
Step 1 of Thermostat User
Configuration Menu must
be set to MS 2
W
First Stage Heat
E/W1
First Stage Heat
Connection of the “C”
Terminal, 24-Volt Common,
is optional when used with
batteries