FIGURE 14.  Q-VENT CE50 DIMENSIONS

15.   SERVICING & MAINTENANCE

IMPORTANT: 

Before commencing any servicing or component replacement ensure the electrical supplies to the unit 

and ancillary control are ISOLATED.
15.1 

The unit will need inspecting on a regular basis. The fan should be cleaned to ensure there is no build-up of 
dirt or other deposits.

 

NOTE: 

The fan is a sealed unit and will not need lubrication.

15.2 

Disconnect the ducting from the spigots and wipe the inside clean with a damp cloth.

15.3 

If replacements part are needed telephone Johnson & Starley Ltd 01604 762881 for further information.

16.   USERS INSTRUCTIONS

16.1 

Hand the User Instructions to the householder, explain and demonstrate how to use the unit.

16.2 

Show how the unit is turned on at the fused spur.

16.3 

The unit will now commence extraction at the minimum set speed.

16.4 

If the unit is fitted with remote automatic boost switch, demonstrate how the boost works by automatically 
boosting the airflow to a predetermined extract rate.

16.5 

The period of time the unit will run at boost speed will depend upon the type of automatic boost control fitted.

16.6 

Explain the unit will need inspecting and cleaning on an annual basis. See section 15 for cleaning the fan 
and spigots. 

 

17. DIMENSIONS

A

C

B

D

E

A

C

B

D

E

Содержание Q-VENT CE50

Страница 1: ...www johnsonandstarley co uk Publication No ZZ 1516 3 May 2016 Q VENT CE50 Central Extract System INSTALLATION COMMISSIONING SERVICING INSTRUCTIONS ...

Страница 2: ...lations 4 5 Safety Electrical Water Information 4 6 Technical Data 4 7 Preparation Positioning 4 Ducting Information Positioning The Unit Spigots Handing 8 Duct Duct Connections 5 9 Installation Instructions 5 10 Electrical 6 Electrical Wiring Options Over Heat Protection 11 Specific Fan Performance 7 12 Sound Spectrum 7 13 Circuit Diagram 8 14 Commissioning 8 Pre Commissioning Check Installer Mod...

Страница 3: ...ir is discharged to outside via a single duct and grille 3 2 The case is constructed from EPP an expanded polypropylene 5 4 3 2 2 7 9 14 1 8 8 9 11 6 13 12 10 1 ITEM DESCRIPTION QTY 1 Q Vent CE50 1 2 Fixing Kit 1 M5 x 25mm Washers 4 No 8 x 50mm Wood Screws 4 Rawl Plugs 4 16mm Screw Spacers 2 3 Template 1 4 Installation Users Instructions 1 FEATURES 7 LED Light 8 Main Supply Cable 9 4 Way Terminal ...

Страница 4: ...When installing the unit take care not to damage electrical or other hidden utilities 5 1 9 Exhaust air must be vented to the outside 5 1 10 The fan motor is fitted with sealed for life bearings and therefore does not require lubrication 6 TECHNICAL DATA 7 PREPARATION POSITIONING 7 1 DUCT INFORMATION 7 1 1 It is an advantage to have all the compatible ductwork already installed and ready to connec...

Страница 5: ...When inserting 100mm ducting into the spigot ensure it is no longer the 45mm 8 3 Where rigid ducting is used it should be installed using the least number of fittings to minimise resistance to air flow Where possible final connection from the rigid ducting to grilles and the unit should be made with a flexible connection 8 4 The exhaust air must exit to outside through either a wall or a roof and ...

Страница 6: ...r the unit 10 5 ELECTRICAL WIRING OPTIONS 10 5 1 A facility is included which boosts the fan duty as required The boost can be achieved by the following method 10 5 2 Connecting black wire from the mains lead to an external 230V AC live source e g bathroom double pole light switch or humidistat 10 6 OVER HEAT PROTECTION 10 6 1 The fan motor is fitted with standard thermal Overload Protection This ...

Страница 7: ...M 11 SPECIFIC FAN PERFORMANCE NOTE Performance graphs shown for two extracts kitchen bathroom FIGURE 7 FAN PERFORMANCE GRAPH TABLE 2 SPECIFIC FAN POWER NAME SPF EXTRACT RATE Kitchen 1 0 25 W L s 21 L s Kitchen 2 0 28 W L s 29 L s Kitchen 3 0 35 W L s 37 L s Kitchen 4 0 42 W L s 45 L s ...

Страница 8: ...w for situations where the unit is not taken out of installer mode 14 2 1 To activate Installer Mode Isolate the electrical supply wait 5 seconds and reconnect 14 2 2 When installer mode is ready the red LED indicator will start flashing every second Now extract and supply fans can be adjusted 14 2 3 To set trickle see paragraph 14 3 4 14 2 4 To set boost see paragraph 14 4 4 14 2 5 Once both sett...

Страница 9: ... 2 Activate Installer Mode 14 4 3 To adjust the BOOST setting turn RV1 clockwise to increase the airflow rate and anti clockwise to decrease the airflow rate to required setting 14 4 4 When the boost airflow is set to the desired rate exit Installer Mode IMPORTANT NOTE After fan speed setting has been completed and the unit is no longer in installer mode the RV1 Fan adjust boost overrun is used to...

Страница 10: ... needed telephone Johnson Starley Ltd 01604 762881 for further information 16 USERS INSTRUCTIONS 16 1 Hand the User Instructions to the householder explain and demonstrate how to use the unit 16 2 Show how the unit is turned on at the fused spur 16 3 The unit will now commence extraction at the minimum set speed 16 4 If the unit is fitted with remote automatic boost switch demonstrate how the boos...

Страница 11: ...E 165 Q VENT CE50 EXPLODED DIAGRAM 18 EXPLODED DIAGRAM 19 SPARE LIST ITEM PART No DESCRIPTION QTY 1 1000 0525605 PCB Assembly 1 2 CE50 0520005 Fan Assembly 1 3 a b 1000 0028825 Outer Fan Casing 2 part set 1 4 CE50 0105005 PCB Cover Plate 1 2 1 3a 3b 4 ...

Страница 12: ... sales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 In the interest of continuous development Johnson Starley reserve the right to change specifications without prior notice Anniversary 1922 2012 ...

Отзывы: