background image

www.johnsonandstarley.co.uk

2

In the interest of continuous development Johnson and Starley reserve the right to change specification without prior notice. 

Johnson and Starley prides itself on it’s ability to supply spare parts quickly and efficiently. If your service engineer indicates a 

problem in obtaining a spare part, advise him to contact Johnson and Starley Spares Department.

CONTENTS

1 Features 

3

2  Carton Content 

3

3  General Description 

3

4  Building Standards & Regulations 

4

5  Safety, Electrical & Water Information 

4

6  Technical Data 

4

7  Preparation & Positioning 

4

 

 

Ducting Information

 

 

Positioning The Unit

   Spigots

   Handing

8  Duct & Duct Connections 

5

9  Installation Instructions 

5

10 Electrical 

6

 

 

Electrical Wiring Options

 

 

Over Heat Protection

11  Specific Fan Performance 

7

12  Sound Spectrum 

7

13  Circuit Diagram 

8

  

14 Commissioning 

8

 

 

Pre- Commissioning Check

 

 

Installer Mode

 

 

Trickle Airflow Adjustment Only

 

 

Boost Airflow Adjustment Only 

 

 

DIP Switch Settings

15  Servicing & Maintenance 

10

 

 

 

Servicing Carried Out With Fans in Place 

 

 

Systems Maintenance: Check Owner Regime

16  Users Instructions 

10

17 Dimensions 

10

18  Exploded Diagram 

11

19  Spares List 

11

Содержание Q-VENT CE50

Страница 1: ...www johnsonandstarley co uk Publication No ZZ 1516 3 May 2016 Q VENT CE50 Central Extract System INSTALLATION COMMISSIONING SERVICING INSTRUCTIONS ...

Страница 2: ...lations 4 5 Safety Electrical Water Information 4 6 Technical Data 4 7 Preparation Positioning 4 Ducting Information Positioning The Unit Spigots Handing 8 Duct Duct Connections 5 9 Installation Instructions 5 10 Electrical 6 Electrical Wiring Options Over Heat Protection 11 Specific Fan Performance 7 12 Sound Spectrum 7 13 Circuit Diagram 8 14 Commissioning 8 Pre Commissioning Check Installer Mod...

Страница 3: ...ir is discharged to outside via a single duct and grille 3 2 The case is constructed from EPP an expanded polypropylene 5 4 3 2 2 7 9 14 1 8 8 9 11 6 13 12 10 1 ITEM DESCRIPTION QTY 1 Q Vent CE50 1 2 Fixing Kit 1 M5 x 25mm Washers 4 No 8 x 50mm Wood Screws 4 Rawl Plugs 4 16mm Screw Spacers 2 3 Template 1 4 Installation Users Instructions 1 FEATURES 7 LED Light 8 Main Supply Cable 9 4 Way Terminal ...

Страница 4: ...When installing the unit take care not to damage electrical or other hidden utilities 5 1 9 Exhaust air must be vented to the outside 5 1 10 The fan motor is fitted with sealed for life bearings and therefore does not require lubrication 6 TECHNICAL DATA 7 PREPARATION POSITIONING 7 1 DUCT INFORMATION 7 1 1 It is an advantage to have all the compatible ductwork already installed and ready to connec...

Страница 5: ...When inserting 100mm ducting into the spigot ensure it is no longer the 45mm 8 3 Where rigid ducting is used it should be installed using the least number of fittings to minimise resistance to air flow Where possible final connection from the rigid ducting to grilles and the unit should be made with a flexible connection 8 4 The exhaust air must exit to outside through either a wall or a roof and ...

Страница 6: ...r the unit 10 5 ELECTRICAL WIRING OPTIONS 10 5 1 A facility is included which boosts the fan duty as required The boost can be achieved by the following method 10 5 2 Connecting black wire from the mains lead to an external 230V AC live source e g bathroom double pole light switch or humidistat 10 6 OVER HEAT PROTECTION 10 6 1 The fan motor is fitted with standard thermal Overload Protection This ...

Страница 7: ...M 11 SPECIFIC FAN PERFORMANCE NOTE Performance graphs shown for two extracts kitchen bathroom FIGURE 7 FAN PERFORMANCE GRAPH TABLE 2 SPECIFIC FAN POWER NAME SPF EXTRACT RATE Kitchen 1 0 25 W L s 21 L s Kitchen 2 0 28 W L s 29 L s Kitchen 3 0 35 W L s 37 L s Kitchen 4 0 42 W L s 45 L s ...

Страница 8: ...w for situations where the unit is not taken out of installer mode 14 2 1 To activate Installer Mode Isolate the electrical supply wait 5 seconds and reconnect 14 2 2 When installer mode is ready the red LED indicator will start flashing every second Now extract and supply fans can be adjusted 14 2 3 To set trickle see paragraph 14 3 4 14 2 4 To set boost see paragraph 14 4 4 14 2 5 Once both sett...

Страница 9: ... 2 Activate Installer Mode 14 4 3 To adjust the BOOST setting turn RV1 clockwise to increase the airflow rate and anti clockwise to decrease the airflow rate to required setting 14 4 4 When the boost airflow is set to the desired rate exit Installer Mode IMPORTANT NOTE After fan speed setting has been completed and the unit is no longer in installer mode the RV1 Fan adjust boost overrun is used to...

Страница 10: ... needed telephone Johnson Starley Ltd 01604 762881 for further information 16 USERS INSTRUCTIONS 16 1 Hand the User Instructions to the householder explain and demonstrate how to use the unit 16 2 Show how the unit is turned on at the fused spur 16 3 The unit will now commence extraction at the minimum set speed 16 4 If the unit is fitted with remote automatic boost switch demonstrate how the boos...

Страница 11: ...E 165 Q VENT CE50 EXPLODED DIAGRAM 18 EXPLODED DIAGRAM 19 SPARE LIST ITEM PART No DESCRIPTION QTY 1 1000 0525605 PCB Assembly 1 2 CE50 0520005 Fan Assembly 1 3 a b 1000 0028825 Outer Fan Casing 2 part set 1 4 CE50 0105005 PCB Cover Plate 1 2 1 3a 3b 4 ...

Страница 12: ... sales johnsonandstarley co uk marketing johnsonandstarley co uk Reception Customer Service 01604 762881 Fax 01604 767408 In the interest of continuous development Johnson Starley reserve the right to change specifications without prior notice Anniversary 1922 2012 ...

Отзывы: