Installation shall be in accordance with the current editions of:-
Building Standards (Scotland) (Consolidation) Regulations
Building Regulations
Gas Safety (Installation and Use) Regulations (as amended)
BS7671 Institute of Electrical Engineers (IEE.) Wiring Regulations
BS6891 Installation of Low Pressure Gas Pipework of up to 28mm (R1) in domestic premises (2nd family gases).
BS5440 Pt.1 (Flues for Gas Appliances)
BS5440 Pt.2 (Air Supply for Gas Appliances)
BS5864 Installation of Gas Fired Ducted Air Heaters
British System Design Manual “Gas Fired Warm Air Heating”
Model and Local Authority Bye-laws

IMPORTANT: STATUTE LAW DEFINES THAT ALL GAS APPLIANCES MUST BE INSTALLED BY COMPETENT
PERSONS, (i.e. CORGI REGISTERED INSTALLERS) IN ACCORDANCE WITH THE GAS SAFETY (INSTALLATION
AND USE) REGULATIONS (CURRENT EDITION). FAILURE TO COMPLY WITH THESE REGULATIONS MAY
LEAD TO PROSECUTION.

2.

HEATER COMPARTMENT AND CLEARANCES

 (See BS5864)

2.1

A minimum clearance of 15mm (

5

/

8

 in) at either side of the heater, and 150mm (6in) above the heater, should be allowed.

For service access, a minimum of 450mm (18in) is required at the front of the heater, and 75mm at the left hand side.
Space must also be allowed, in a compartment installation, to permit the removal of the heater. If a Cleanflow electronic
air filter is to be fitted in the compartment, allowance must be made for this in the width of the compartment. The
compartment must be of a fixed rigid structure and the internal construction must be of half-hour fire resistance to
internal fire; the inside lining or finishing of the enclosure must be noncombustible or a class 1 finish (see also BS 476).

2.2

In airing cupboard installations, the part used as the air heater compartment must comply with the relevant section of
BS 5864 and must be completely separated by either a non-combustible partition or a perforated metal partition with the
perforations not exceeding 13mm (0.5in).

2.3

In under-stair installations, the compartment must comply with the relevant section of BS5864, provided that, in addition,
all internal surfaces, including the base, are of, or lined with non-combustible material.

3.

VENTILATION AND COMBUSTION AIR

3.1

A room sealed appliance does not require a combustion air vent in the room or internal space in which it is installed. If
the appliance is installed in a compartment, the minimum total free area of the high and low level ventilation air vents
must be as specified in Table 1 below, (in reference to BS5440 Pt 2, Table 1).

2

ZZ 1019/1E

Position of

Air from room

Air direct

air vents

or internal space

from outside

High level

89cm

2

 (14 in

2

)

45cm

2

 (7 in

2

)

Low level

89cm

2

 (14 in

2

)

45cm

2

 (7 in

2

)

TABLE 1

MINIMUM EFFECTIVE AREAS

4.

ADAPTING TO RIGHT HAND AIR ENTRY

4.1

Remove the return air spigot and the short side cover from the left hand side of the appliance, and lay to one side.

4.2

Remove the long side cover from the right hand side of the appliance, and reassemble it on the left hand side, ensuring
that the 

slots are towards the front

 of the appliance.

4.3

Reassemble the short side cover and the return air spigot ton the right side of the appliance, ensuring that the 

slots in the

side cover are towards the front

 of the appliance.

5.

DUCT SYSTEM

(See British Design Manual - Gas Fired Warm Air Heating).

IMPORTANT:  All duct work MUST be mechanically secured, and sealed with ducting tape.

5.1

RETURN AIR

5.1.1

Room sealed appliances may be installed without return air ducting, provided that the path between the return air
grille and the appliance return air inlet is protected in such a manner that the required airflow will be maintained at
all times. Where no ducting is fitted, a finger guard (Ref. ***, available from Johnson and Starley Ltd.), MUST be
fitted.

15

Fig. 9 Principal dimensions (mm)

ZZ 1019/1E

Содержание JANSTAR Mk 2

Страница 1: ...Key Description Key Description 1 Air circulating fan 7 Air filter L H shown 2 Burner assembly 8 Flue outlet combustion air inlet 3 Ignition detection electrode 9 Fan to flue connection 4 Gas connecti...

Страница 2: ...ely separated by either a non combustible partition or a perforated metal partition with the perforations not exceeding 13mm 0 5in 2 3 In under stair installations the compartment must comply with the...

Страница 3: ...es For applications where the flue exits directly through a wall the telescopic flue supplied with the heater may be used as shown in Fig 2 6 2 3 The horizontal flue shall be installed with horizontal...

Страница 4: ...e application Fig 4 Flue jointing Fig 6 Electrical panel ZZ 1019 1E 13 Ignition Control Unit Control Module Fuse Fan speed selector Air Heating Summer Airflow switch Burner ON indicator Fig 7 JANSTAR...

Страница 5: ...SSIONING 7 1 Ensure the following 7 1 1 Gas and Electrical supplies are OFF 7 1 2 Filter fan and fan compartments are free from obstructions 7 1 3 All registers or grilles are open and conform to desi...

Страница 6: ...essary Note It is possible to obtain a spark even when the electrode lead is damaged but the lead may not be able to conduct the very small detection current to the ignition detection control If there...

Страница 7: ...inal marked C3 d BROWN lead from the terminal marked C4 e YELLOW lead from the terminal marked C5 f YELLOW lead from the terminal marked C6 g RED lead from the terminal marked C7 h BLACK lead from the...

Страница 8: ...swing down and support the electrical panel ensuring that no strain is place upon or any damage is caused to any electrical wiring or connections 9 5 5 Remove the air circulation fan securing screw a...

Страница 9: ...swing down and support the electrical panel ensuring that no strain is place upon or any damage is caused to any electrical wiring or connections 9 5 5 Remove the air circulation fan securing screw a...

Страница 10: ...inal marked C3 d BROWN lead from the terminal marked C4 e YELLOW lead from the terminal marked C5 f YELLOW lead from the terminal marked C6 g RED lead from the terminal marked C7 h BLACK lead from the...

Страница 11: ...essary Note It is possible to obtain a spark even when the electrode lead is damaged but the lead may not be able to conduct the very small detection current to the ignition detection control If there...

Страница 12: ...SSIONING 7 1 Ensure the following 7 1 1 Gas and Electrical supplies are OFF 7 1 2 Filter fan and fan compartments are free from obstructions 7 1 3 All registers or grilles are open and conform to desi...

Страница 13: ...e application Fig 4 Flue jointing Fig 6 Electrical panel ZZ 1019 1E 13 Ignition Control Unit Control Module Fuse Fan speed selector Air Heating Summer Airflow switch Burner ON indicator Fig 7 JANSTAR...

Страница 14: ...es For applications where the flue exits directly through a wall the telescopic flue supplied with the heater may be used as shown in Fig 2 6 2 3 The horizontal flue shall be installed with horizontal...

Страница 15: ...ely separated by either a non combustible partition or a perforated metal partition with the perforations not exceeding 13mm 0 5in 2 3 In under stair installations the compartment must comply with the...

Страница 16: ...Key Description Key Description 1 Air circulating fan 7 Air filter L H shown 2 Burner assembly 8 Flue outlet combustion air inlet 3 Ignition detection electrode 9 Fan to flue connection 4 Gas connecti...

Отзывы: