background image

 

– 8 – 

PART NO. 100266523 

 WATER  ODOR/SACRIFICIAL  ANODE

Your storage tank has been equipped with one magnesium 
anode that will slowly deplete while protecting the glass-lined 
tank thus prolonging its life. Certain water conditions may 
cause a reaction between the anode and the water. The most 
common complaint associated with the anode is a “rotten egg 
smell” produced by the presence of sulfur. Do not remove 
this anode permanently as it will void any warranties, stated 
or implied. An aluminum anode may reduce if not eliminate 
water odor problems. The water supply system may require 
special 

fi

 ltration equipment from a water conditioning company 

to successfully eliminate all water odor problems. Arti

fi

 cially 

softened water is exceedingly corrosive because the process 
substitutes sodium ions for magnesium and calcium ions. The 
use of a water softener may decrease the life of the water 
heater tank. The anode should be inspected periodically. If 
the anode is more than 50% depleted, the anode should be 
replaced.

 ANODE  MAINTENANCE

• 

Flammable hydrogen gases may 

be present.

• 

Keep all ignition sources away 

from faucet when turning on hot 
water.

Explosion Hazard

WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot 
water system that has not been used for a long period of time 
(generally two weeks or more). Hydrogen gas is extremely 

fl

 ammable and explosive. To prevent the possibility of injury 

under these conditions, we recommend the hot water faucet, 
located farthest away, be opened for several minutes before 
any electrical appliances which are connected to the hot water 
system are used (such as a dishwasher or washing machine). 
If hydrogen gas is present, there will probably be an unusual 
sound similar to air escaping through the pipe as the hot water 
faucet is opened. There must be no smoking or open 

fl

 ame 

near the faucet at the time it is open.

1.  Turn "OFF" the electrical supply to the tank.
2.  Close the cold water supply valve.
3.  Open a nearby hot water faucet served by the system to 

depressurize the system.

4.  Connect a hose to the drain valve and drain 22 litres 

(6 gal.) as directed in the "Draining and Flushing" section.

5.  Using an adjustable pipe wrench, remove the anode 

and inspect it. The surface may be rough, full of pits and 
crevices, but this is normal. If it is less than approximately 
6mm (1/4 in.) in diameter, or the inner steel core is 
exposed, the anode should be replaced.

6. Apply 

Teflon

TM

 tape or sealing compounds approved for 

use with potable water, to the threads of the anode and 
install into the tank top.

7.  Open the cold water supply valve and open a nearby hot 

water faucet to purge air from the tank as directed in the 
"Filling" section.

8.  Check for leaks, repair as required, and re-test.
9.  Turn "ON" the electrical supply to the tank.

Содержание FlowThru GST

Страница 1: ...ouch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions If you cannot reach your gas supplie...

Страница 2: ...irculator Pump 4 Sizing The Hot Water System 4 Plumbing Connections 4 Electrical Wiring 6 Filling 6 OPERATION 6 Temperature Adjustment 6 Initial Temperature Adjustment 7 Temperature Limit Control 7 MA...

Страница 3: ...rom the valve will exit within 152mm 6 in above or any distance below the structural floor and cannot contact any live electrical part The end of the relief pipe opening should terminate near the floo...

Страница 4: ...ater entering the tankless coil boiler must be tempered with hot water from the storage tank As there is a large variety of heat sources and control systems please contact your local distributor for t...

Страница 5: ...al Set the mixing valve outlet temperature to 49 C 120 F to avoid scalding 7 Acheck valve may be installed in the cold water line before the connecting tee Note The check valve can often be noisy and...

Страница 6: ...suitable drain Open the drain valve and let water run to flush out any foreign matter that may have entered the system Once flushed close the drain valve and disconnect hose OPERATION 1 Follow boiler...

Страница 7: ...etely reset and continues to release water immediately turn OFF the electrical supply to the tank close the cold water supply valve and call a qualified service technician TEMPERATURE AND PRESSURE REL...

Страница 8: ...e generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possibility of injury under these conditions we recommend the hot water faucet located farthest away be o...

Страница 9: ...y period shown in the table above after the original installation the Manufacturer will furnish the Owner with a replacement for the defective part s This Warranty is limited to one replace ment compo...

Страница 10: ...tingency beyond the control of the Manufacturer or s The water heater is installed in a closed system without adequate provision for thermal expansion 3 Except when specifically prohibited by the appl...

Отзывы: