Replacement of the
connection cable
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel with similar
competencies, in accordance with
the current regulations.
To replace the connection cable
use only H03V2V2-F T90 or
equivalent type. Make sure that the
cable section is applicable to the
voltage load and the working
temperature. The yellow/green
earth wire (B) must be
approximately 2 cm longer than the
live and neutral wire (A).
A
B
1. Connect the green and yellow (earth) wire to
the terminal which is marked with the letter 'E',
or the earth symbol
, or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
Assembly
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
min. 200 mm
30 mm
480 mm
min. 600 mm
4.
50 mm
400 mm
Hob User Manual
19