John Guest Speedfit Скачать руководство пользователя страница 9

Water-replenishing  ring  mains  are  typically  used  in  hotels
and  hospitals.  They  are  maintained  at  a  constant  high
temperature  to  supply  hot  water  to  distribution  pipes  to
wards  or  hotel  rooms  which  may  be  some  way  from  the
heat source.

These  systems  are  very  different  from  more  conventional
domestic hot water and central heating systems.

Speedfit  Products  cannot  be  used  on  ring  main  systems.
The  exception  would  be  those  systems  designed  for
domestic  situations  which  have  an  intermittent
temperature  of  less  than  a  maximum  of  65ºC.  This  is  in
accordance with BS7291 Parts 1 and 3 Class S.

P

ART

N

O

.

JG-TS

P

ART

N

O

.

JG HDC
BLADE-JGHDC

P

ART

N

O

.

S

IZE MM

PC15W

15

PC22W

22

PC28W

28

PCSW

For up to 22mm size pipe.

P

ART

N

O

.

S

IZE MM

NPC10

10

NPC15

15

NPC22

22

NPC28

28

P

ART

N

O

.

S

IZE MM

10CFB

10

15CFB

15

22CFB

22

To help create a tighter bend than 
the minimum with unsupported pipe.   

P

ART

N

O

.

S

IZE MM

JG-BS10

10

JG-BS15

15

JG-BS22

22

For use with Female Coupler/Tap Connector.

PLUMBING SPARE PARTS

P

ART

N

O

.

S

IZE MM

PXC 10

10

PXC 15 

15

SPF 22

22

PXC 28

28

PXC 10

10

PXC 15

15

PXC 22

22

PXC 28

28

P

ART

N

O

.

S

IZE MM

10 EPR

10

15 EPR

15

22 EPR

22

28 EPR

28

P

ART

N

O

.

S

IZE

1/2 EPW

1/2

3/4 EPW

3/4

10mm

15mm and 22mm

P

ART

N

O

.

S

IZE MM

10RA

10

15RA

15

22RA

22

28RA

28

PIPE AND PIPE ACCESSORIES

For Standard Fittings

For Twist and Locks Fittings

SYSTEM CONNECTIONS

The  Speedfit  Range  includes  couplers  to  connect
Speedfit Pipe to 1/2” to 1” BSP and BSPT.  See page 12.

Many but not all compression fittings are suitable for use
with  plastic  fittings  and  pipe.  Users  should  therefore
check  for  compatibility.  Compression  fittings  with  short
tube stop depth or brass olives should not be used with
plastic fittings or pipe.

When  using  compression  fittings  with  Speedfit  Pipe,  a
Standard  Pipe  Insert  (prefix  TSM)  must  be  used  to
withstand the compressive pressure of the olive. The olive
must  be  located  within  the  the  length  of  the  pipe  insert
and the pipe fully inserted into the fitting. The connection
should not need more than 2 full turns after the olive has
gripped  the  pipe.  JG  Speedfit  recommend  the  use  of  soft
copper olives.

In  modern  properties,  water  enters  a  building  usually  in
blue  MDPE (medium  density  polyethylene)  pipe.  In  order
to  comply  with  Water  Regulation  Schedule  2.10,  the
internal  plumbing  system  should  be  connected  via  a
Speedfit  Stop  Valve  (Part  Nos.  15STV  and  22STV)  in
conjunction with a PE-Copper Coupler from the Speedfit
range of Underground Fittings.

Speedfit fittings can be connected onto chromium plated
copper  pipe  if  the  chromium  plating  is  completely
removed  to  the  full  depth  of  the  fitting.  To  ensure
maximum grip, the fitting of a collet clip is recommended. 

Connection  of  Speedfit
pipe to supply pipe of other
materials should be via a
stop  tap  with  a  15mm  or
22mm compression outlet. 

Compression fitting

Standard Pipe insert

Olive

Speedfit Pipe

with Superseal Pipe Insert

Stop valve

Copper pipe

PE copper coupler

MDPE pipe with

Pipe Insert

Collet clip

Speedfit Pipe

Speedfit pipe should never be connected directly to a boiler.

Although  most  modern  boilers  have  a  high  limit
thermostat,  residual  heat  can  be  conducted  by  the  heat
exchanger. Therefore, Speedfit recommend a minimum of
1  metre  from  the  boiler  casing  should  be  run  in  copper
pipe unless otherwise stated in the boiler manufacturers
installation literature.

A  gravity  primary  circuit  operating  on  an  uncontrolled
cooking range or solid fuel boiler should be run entirely in
copper and the heating circuit run in copper for the first metre.

Refer to BS 5955: Part 8 for further clarification.

All  appliances  should  have  safety  devices  to  make  sure
they cannot operate above the working temperature and
pressure range set out in our Technical Checklist on page
29.  If  safety  devices  are  not  incorporated  within  the
appliance then external controls will be needed. 

Water  meters  (and  other  devices)  can  contain  check
valves  that  prevent  the  expansion  of  heated  water  back
down the main supply from a combi boiler. If plastic pipe
is to be used, a suitable expansion vessel must be fitted.
This is especially important to consider if a water meter is
fitted retrospectively. Speedfit do not recommend the use
of plastic pipe on the main supply between a water meter
and a combi boiler if an expansion vessel is not fitted.

Speedfit Products should not be fitted to a sealed system
oil boiler, back fired boiler or other uncontrolled heat source.

Please  also  see 

Drop-Pipe  Systems

on  page  17  and

System Commissioning and Flushing

on page 21.

Ensure nut and olive are in place before inserting pipe insert.

It is not possible to connect Speedfit fittings to Stainless
Steel Pipe.

Fittings to connect imperial
pipe to metric pipe are
shown on page 10.

RELEASE AID

COLD FORMING BEND

BENDING SPRING

PIPE CUTTER

HEAVY DUTY PIPE CUTTER

PIPE CLIPS AND SPACERS

NAIL CLIP

COLLETS

EPDM ‘O’ RING

THREAD WASHER

CONNECTION TO COMPRESSION FITTING

CONNECTION TO IMPERIAL PIPE AND FITTINGS

CONNECTION TO CHROME-PLATED COPPER PIPE

CONNECTION TO MAINS SUPPLY

CONNECTION TO RING MAINS

CONNECTION TO BOILERS

Speedfit can be used on sealed and open vented heating
systems,  where  boilers  are  either  heating  a  hot  water
storage  cylinder  or  instantaneous  hot  water  such  as  a
combination  boiler.  The  temperature  and  pressure  limits
of  the  system  must  not  exceed  the  maximum  values  stated
under the heading ‘Working Temperatures and Pressures’.

When using a traditional copper vented cylinder Speedfit
pipe and fittings can be installed with direct connections
to the cylinder.

As shown in the Product Range List, the Speedfit range of
fittings includes valves, taps, adaptors and connectors for
the plumbing of all typical domestic appliances and fittings.

CONNECTING TO OTHER PLUMBING FIXTURES

CONNECTION TO CYLINDER & WATER HEATERS

15

16

For up to 28mm size pipe.

Allows a firmer grip on the 
collet when removing pipe.

P

ART

N

O

.

S

IZE MM X M

JGTAPE

50 x 45

FOIL TAPE

Metallic tape to meet NHBC requirements
for plastic pipe to be detected inside walls.

Содержание Speedfit

Страница 1: ...rposes only Subject to our Terms and Conditions of Sale available on request Z2105 217 10 07 No s 95 3177 BS7291 KM39767 AVAILABLE FROM THE PUSH FIT SOLUTION FOR PLUMBING HEATING SYSTEMS UK PRODUCT RA...

Страница 2: ...ducts A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development 01 02 Technical Support Our national team of Technical...

Страница 3: ...s application Speedfit fittings suitable for central heating systems can withstand temperatures up to 114 C intermittently for short periods Speedfit fittings shown as not suitable for central heating...

Страница 4: ...ead The O ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting A good connection has been made Gap between Cap and Flange Pipe mark indicates full insertion Twis...

Страница 5: ...e connectors are useful when replacing existing brassware or in other confined spaces Coupling up to a supply is easy The pipe is simply pushed home into the Speedfit connection and is instantly secur...

Страница 6: ...28 x 22 PEMSTC1514 15mm x 1 2 BSP PEMSTC1516 15mm x 3 4 BSP PEMSTC2216 22mm x 3 4 BSP PEMBTC1514 15mm x 1 2 BSP PART NO SIZE MM PSE4610W 10 PSE4615W 15 PSE4622W 22 Suitable for central heating systems...

Страница 7: ...50mm long 1000mm long PART NO SIZE MM X MALE FLX48 12 x M10 FLX28 15 x M10 FLX29 15 x M12 FOR MONOBLOC MIXERS PART NO SIZE MM X BSP PART NO SIZE MM X BSP FLX36P 15 x 1 2 ELBOW PATTERN 300mm long 300mm...

Страница 8: ...15BPEX 120C 15mm x 120m 15BPEX 150C 15mm x 150m 22BPEX 25C 22mm x 25m 22BPEX 50C 22mm x 50m Suitable for central heating systems Coils The pipe has an inner barrier to stop the ingress of atmosphere...

Страница 9: ...Copper pipe PE copper coupler MDPE pipe with Pipe Insert Collet clip Speedfit Pipe Speedfit pipe should never be connected directly to a boiler Although most modern boilers have a high limit thermost...

Страница 10: ...M M M M M M P P Plastic M Metal NB All Waste Pipes are plastic 1 Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathro...

Страница 11: ...rs does not affect the fire resistant properties of the structure Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind dot and dab plasterboard installatio...

Страница 12: ...ntrolled by one or more thermostats which signal the Pump Pack when heat is required 21 22 RADIATOR SYSTEM AND HEAT GRADIENT UNDERFLOOR HEATING SYSTEM An Underfloor Heating System heats mainly by radi...

Страница 13: ...ntralised control of the set back functions for the whole manifold via a digital programmer The timer acts as a timed switch to alternate between daytime and Set Back time PART DESCRIPTION PACK NO QTY...

Страница 14: ...on of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown below Single Serpentine Double Serpentine Trip...

Страница 15: ...nst the face of fitting With the collet held in this position the pipe can be withdrawn We recommend the replacement of the O ring and collet before making a new connection Remove collet cover pull ou...

Страница 16: ...ulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products Exposure to sunlight Speedfit products when used indoors are not affected...

Отзывы: