 Fittings and pipe should be kept clean and undamaged before use.

Sizes.

10mm to 28mm diameter.

Pipes.

Speedfit fittings can be used with:

Copper pipe to BS EN 1057

Speedfit Barrier Pipe to BS7291.

Speedfit fittings cannot be used on stainless steel pipe.

Standards.

Speedfit products are designed and manufactured 

under a fully integrated system assessed by B.S.I. to BS EN ISO9001. 

They are approved by the WRAS and BBA. Speedfit PEM, PSE and SFM                

Fittings and Speedfit Barrier Pipe are Kitemarked to BS7291 Parts 1, 2 

and 3, Class S. (Licence No. KM39767)

Applications.

Mains fed and indirect cold water systems

Vented and unvented hot water systems

Vented and sealed central heating systems

Do not use for Gas, fuel oil or compressed air applications.

Working temperatures and pressures

Application

Usual working 

Maximum working

Maximum working

temperature, ºC

temperature, ºC

pressure, bar

Cold Water

20

20

12

(indirect and direct mains)

Central Heating

82

105, short term

3

malfunction at 114

Hot Water

65 

95

6

(including unvented cylinders)

Burst Pressure (fittings).

With copper or plastic pipe at 20°C: Speedfit 

fittings used with copper or Speedfit Barrier Pipe will withstand pressures 

well in excess of normal service conditions.

High temperatures.

Can withstand 114°C intermittently for short periods. 

The Speedfit system should not be used on an uncontrolled heat source.

Insulation.

Should comply with BS6700 and BS5422, as for copper.

Minimum bend radii (PEX)

Pipe diameter

10mm 15mm 22mm 28mm

Min radius with clips

100mm 175mm 225mm 300mm

Min radius with cold forming bend 30mm 75mm 110mm

-

Clip spacing (in mm).

For surface mounted pipes

Pipe Diameter

Clip Spacing

Horizontal Run

Vertical Run

10 - 15mm

300mm

500mm

22mm

500mm

800mm

28mm

800mm

1,000mm

Where pipe is concealed, clipping may only be required where necessary.

Expansion (PEX pipe).

1% on length between 20°C and 82°C.

Flow rates.

Comparable with metal systems.

Cleaners, inhibitors and descalents.

For advice on the replenishment of 

additives such as corrosion inhibitors, the following manufacturers should 

be contacted: Fernox Manufacturing Limited on 01799 550811 or Sentinel, 

BetzDearborn Limited on 0151 420 9595.

Paint and Chemicals.

Use only water or oil based paint. Collet covers 

prevent paint ingress into fittings. 

DO NOT ALLOW CONTACT WITH 

oil based jointing compounds, cellulose based paints, paint thinners, paint 

strippers, solder flux, acid based descalents or aggressive cleaning products.

Solder  Flux.

No  fluxes  of  any  types  should  come  into  contact  with 

JG Speedfit Pipe and Fittings. If fluxes are to be used in an environment 

where Speedfit is installed, then (1) extreme care should be taken to ensure

that no such contact  takes place and (2) JG recommend installers only use

fluxes tested and approved in writing in advance by JG. At the date of this 

publication, the only such approved flux is Fernox Flux.

TECHNICAL CHECKLIST - 
PLUMBING AND HEATING FITTINGS

29

30

Applications.

Speedfit Underground Fittings are designed to connect

MDPE pipes (MRS-PE80) used above or below ground, to convey

potable water from distribution mains to individual properties.

Sizes.

20mm and 25mm with adaptors for:-

- Copper to BS2871 Part 1 / BS EN1057. Table X and Table Y.

- Screwed pipe.

- LDPE (to BS1972 Class C and Class D) in 1/2” and 3/4” inch sizes.

Pipes.

Speedfit Underground Fittings can be used with:-

- Blue MDPE pipe to BS6572.

- Black MDPE pipe to BS6730.

- Pipes conforming to ISO161/1, ISO3607 and DIN16893.

Working Temperatures and Pressures.

Maximum working pressure 

12 Bar @ 20˚C.

Standards.

Speedfit Underground Fittings are approved by the 

Water Regulations Advisory Scheme.

Performance.

The fittings are manufactured from tough plastic 

material well able to meet the stringent requirements of the water 

industry. They have been approved by the WRAS and, as such, 

have passed the ʻpull out testʼ where a force shown below is applied 

to a connection between MDPE pipes and a fitting for 5 minutes 

without the connection failing.

Size

Test Force

20mm

25mm

Newtons

1900

2500

lbs

427

562

• DO NOT USE FOR Gas, fuel oil or compressed air applications 

or hot water.

Chemical Effects.

For below ground applications the fittings require 

no additional preparations - coating etc. When used above ground, 

avoid contact with aggressive chemical compounds. Protect from frost

where necessary. In the United Kingdom, potable water does not 

contain high levels of chemicals (eg chlorine etc) that would adversely

affect Speedfit Underground Fittings.

Exposure to sunlight.

Permanent exposure to direct sunlight will 

necessitate lagging the fittings.

Pipe Inserts.

Pipe inserts must be used and fully inserted on all 

connections to MDPE or LDPE pipe.

System Testing.

Pressure test to 1.5 times working pressure for 10 

minutes before connecting to the mains supply. It is recommended 

that all pipe and fitting installations are pressure tested after 

installation before handing over to the final user

Maximum Torque Figures.

The maximum torque figures for BSP

and BSPT threads used on Speedfit products are as follows:-

Size

Maximum Torque

1/2

3.0 Nm

3/4

4.0 Nm

It  is  recommended  that  all  installations  are  checked  prior  to  use  to

determine that a seal has been made.
The  maximum  torque  figures  quoted  for  use  with  Speedfit  fittings  are

dependent  on  the  mating  thread  conforming  to  the  relevant  British

International thread standards.

TECHNICAL CHECKLIST - 
UNDERGROUND FITTINGS

Applications.

Underfloor Heating Installations in solid or timber floors.

Pipes.

15mm JG Speedfit Barrier Pipe to BS 7291, Parts 1, 2 and 3 Class S.

DO NOT USE 

Speedfit UFH Products for Gas, fuel oil or compressed 

air applications.

Floor Insulation.

Should be a suitable material and thickness to comply 

with current regulations.

Minimum Bending Radii.

For Speedfit B-PEX Pipe is 175mm.

Expansion (PEX - Pipe).

1% on length between 20˚C and 82˚C.

Cleaners, Inhibitors and Descalents.

For advice on the replenishment of

additives such as corrosion inhibitors, the following manufacturers 

should be contacted Fernox Manufacturing Limited on 01799 550811 or 

Sentinel, BetzDearborn Limited on 0151420 9595.

Paint and Chemicals.

Only use water or oil based paint. DO NOT ALLOW

CONTACT WITH cellulose based paints, paint thinners or strippers, solder 

flux or acid based descalents or aggressive household cleaning products.

Exposure to sunlight.

Speedfit products, when used indoors, are not 

affected by sunlight. When used out doors protect from ultra violet light 

by lagging or painting.

Pipe Inserts.

Must be used on all installations when using plastic pipe and

should be fully inserted.

Electrical Components.

Electrical products in the Speedfit Underfloor Heating 

Systems are designed only to be used in U.K. Electrical Supply situations.

Electrical Continuity.

If Speedfit is used in an existing metal system which

may have been used for earthing, electrical continuity should be reinstated.

Collet Clips. 

White and Grey collet clips are used with standard fittings to 

prevent accidental pipe disconnection. Red or blue clips provide colour 

coding of pipe. Red and blue clips should not be used to prevent accidental

release of pipe.

Pre-Screed System Testing. 

To ensure the pipework has been installed 

correctly and prior to the screed being laid, it is essential that the system 

is checked and hydraulically wet tested.

Testing should be carried out at 2 bar for 10 minutes and 10 bar for 
10 minutes.

This testing, combined with other relevant checks, should reveal installation

problems and is regarded as good plumbing practice.

• Pressurisation During Screed Laying & Curing.

In accordance with 

BS1264-4, the system should be left under pressure at a minimum of 6 bar for 
the duration of the laying and curing of the screed.

Under  NO  circumstances  should  the  UFH  System  be  used  to  quicken
the screed drying process.  

System Flushing.

As is usual practice for any plumbing installation, 

flushing of the system prior to the use of JG Speedfit is recommended to 

remove any contaminants/chemical residue from elsewhere in the system.

Vermin.

Speedfit products should not be used in vermin infested areas.

Frost Protection.

During the installation process it is important that pipe 

containing water be protected from frost.

TECHNICAL CHECKLIST -
UNDERFLOOR HEATING 

Chlorine. 

Speedfit is not suitable for use in systems where the water 

contains high levels of chlorine. e.g. swimming pools, fountains etc.

Exposure to sunlight.

Speedfit products, when used indoors, are not 

affected by sunlight. When used outdoors protect from ultra violet light 

by lagging or painting. 

Pipe clips.

Pipe clips should not be fitted any closer than 60mm from the

end of the fitting. Pipe should be adequately supported by pipe clips to 

prevent undue stress (side load) on fittings.

Pipe inserts.

Must be used on all installations when using plastic pipe 

and should be fully inserted. Only use a Speedfit Insert with Speedfit Pipe.

Metal Joists.

When ʻcablingʼ plastic pipe through metal joists ensure rubber

grommets are in place to prevent damage to pipe. Use of collet covers or 

collet clips on fittings recommended.

Connection to boilers.

A minimum 1000mm run of copper pipe must be 

installed between the boiler and the Speedfit system, as per BS5955: Part 8.

Connection to copper pipe.

450mm is the minimum distance to make 

a solder connection on copper pipe inserted into a Speedfit Fitting. Ensure 

that any residual flux solder does not come into contact with the fitting.    

Concrete and masonry.

Speedfit pipe and fittings can be laid in concrete 

and masonry providing they are installed in conduit pipe with access boxes

for the fittings. This is to enable the pipe to expand and provide accessibility

for both pipe and fittings. As stated in Water Regulation Scheme 2.7 and BS

8000 : Part 15, fittings and pipe should be removable for possible replacement.

Insulation is also recommended to protect against heat loss and the effects 

of frost.

Electrical continuity.

If Speedfit is used in an existing metal system which 

may have been used for earthing, electrical continuity should be reinstated.

Valves and taps.

Plastic 15mm and 22mm valves and taps available from 

JG Speedfit Ltd are not suitable for central heating installations.

Collet Covers.

Collet covers provide added security against pipe 

disconnection, e.g. the fittings coming into contact with rigid surfaces 

and behind dry-lining walls. They are offered in white as standard and 

in red or blue to provide colour coding of pipe.

Collet Clips.

Grey collet clips are used with standard fittings to prevent 

accidental pipe disconnection. Red or blue clips provide colour coding 

of pipe. Red and blue clips should not be used to prevent accidental 

release of pipe.

• System testing.

To ensure the pipework and fittings have been installed 

correctly, whether it be on a new or extended system, it is essential that the 

system is checked and hydraulically wet tested. Testing should be at 2 bar 

for 10 minutes and 10 bar for 10 minutes. This testing, combined with other 

relevant checks, should reveal installation problems and is regarded as good 

plumbing practice. However, system testing should not be regarded as a 

substitute for correct installation (see also “Making a Good Connection”).

System flushing.

As is usual practice for any plumbing installation, flushing

of the system prior to the use of Speedfit is recommended to remove any

contaminants/ chemical residue from elsewhere in the system.

British Gas Service has accepted the John Guest Speedfit fittings as being 

suitable for open vented and sealed central heating systems and as eligible

for acceptance onto its service contracts.

Vermin.

Speedfit products will need special protection in vermin infested areas.

Maximum Torque figures (BSP & BSPT).

Plastic threads are not generally as

strong as brass threads. Customers and end users should be aware of this 

when choosing products for their applications. Overtightening of plastic threads 

will cause undue stress and eventual cracking and leakage. The maximum 

torque figures for BSP and BSPT threads used on Speedfit plumbing products 

in mating threads conforming to the relevant BS or International thread 

standards are shown below.

Threads

Size

Maximum Torque

Plastic

1/2”

3.0 Nm

3/4”

4.0 Nm

Brass

1/2”

4.0 Nm

3/4”

5.0 Nm

It is recommended that all installations are checked prior to use to determine 

that seal has been made.

Side Loads.

Fittings should not be subject to excessive side loads and they 

should not be used as support brackets. Tubing and fittings should be adequately 

supported to prevent excessive side loading. 

Содержание Speedfit

Страница 1: ...rposes only Subject to our Terms and Conditions of Sale available on request Z2105 217 10 07 No s 95 3177 BS7291 KM39767 AVAILABLE FROM THE PUSH FIT SOLUTION FOR PLUMBING HEATING SYSTEMS UK PRODUCT RA...

Страница 2: ...ducts A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development 01 02 Technical Support Our national team of Technical...

Страница 3: ...s application Speedfit fittings suitable for central heating systems can withstand temperatures up to 114 C intermittently for short periods Speedfit fittings shown as not suitable for central heating...

Страница 4: ...ead The O ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting A good connection has been made Gap between Cap and Flange Pipe mark indicates full insertion Twis...

Страница 5: ...e connectors are useful when replacing existing brassware or in other confined spaces Coupling up to a supply is easy The pipe is simply pushed home into the Speedfit connection and is instantly secur...

Страница 6: ...28 x 22 PEMSTC1514 15mm x 1 2 BSP PEMSTC1516 15mm x 3 4 BSP PEMSTC2216 22mm x 3 4 BSP PEMBTC1514 15mm x 1 2 BSP PART NO SIZE MM PSE4610W 10 PSE4615W 15 PSE4622W 22 Suitable for central heating systems...

Страница 7: ...50mm long 1000mm long PART NO SIZE MM X MALE FLX48 12 x M10 FLX28 15 x M10 FLX29 15 x M12 FOR MONOBLOC MIXERS PART NO SIZE MM X BSP PART NO SIZE MM X BSP FLX36P 15 x 1 2 ELBOW PATTERN 300mm long 300mm...

Страница 8: ...15BPEX 120C 15mm x 120m 15BPEX 150C 15mm x 150m 22BPEX 25C 22mm x 25m 22BPEX 50C 22mm x 50m Suitable for central heating systems Coils The pipe has an inner barrier to stop the ingress of atmosphere...

Страница 9: ...Copper pipe PE copper coupler MDPE pipe with Pipe Insert Collet clip Speedfit Pipe Speedfit pipe should never be connected directly to a boiler Although most modern boilers have a high limit thermost...

Страница 10: ...M M M M M M P P Plastic M Metal NB All Waste Pipes are plastic 1 Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathro...

Страница 11: ...rs does not affect the fire resistant properties of the structure Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind dot and dab plasterboard installatio...

Страница 12: ...ntrolled by one or more thermostats which signal the Pump Pack when heat is required 21 22 RADIATOR SYSTEM AND HEAT GRADIENT UNDERFLOOR HEATING SYSTEM An Underfloor Heating System heats mainly by radi...

Страница 13: ...ntralised control of the set back functions for the whole manifold via a digital programmer The timer acts as a timed switch to alternate between daytime and Set Back time PART DESCRIPTION PACK NO QTY...

Страница 14: ...on of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown below Single Serpentine Double Serpentine Trip...

Страница 15: ...nst the face of fitting With the collet held in this position the pipe can be withdrawn We recommend the replacement of the O ring and collet before making a new connection Remove collet cover pull ou...

Страница 16: ...ulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products Exposure to sunlight Speedfit products when used indoors are not affected...

Отзывы: