background image

Installation, Operation & Maintenance Instructions  

1

API PLAN 74

SEAL SYSTEMS 

1. General

1.1 Introduction

Plan 74 may only be installed, commissioned and maintained by an 

authorized plant machinery specialist, paying close attention to these 

instructions and all other relevant regulations. Failure to do this relieves 

the manufactures from any liability or warranties. 
This Instruction Manual is provided to familiarize the user with the 

Plan 74 arrangement and its use. The instructions must be read and 

applied whenever work is done on the Plan 74, and must be available to 

operating and maintenance personnel.
These instructions will help to avoid danger and increase reliability. They 

should be used with the appropriate mechanical seal Instruction Manual.
The following important terms and definitions are used in this document.

1.2 European and/or UK Declaration of Incorporation
(Machinery Directive 2006/42/EC, and UK SI 2008 No. 1597) 

If appropriate this is attached.

1.3 European Declaration of Conformity  
(Pressure Equipment Directive, 2014/68/EU)

This directive is not applicable to Plan 74.

1.4 European and/or UK Declaration of Conformity 
(ATEX 2014/34/EU, and Equipment and UK SI 2016 No. 1107)

These instructions are intended for use with system operating in 

Equipment Group II, category 2GD.
The Declaration covers the complete seal and system and the maximum

surface temperature is recorded in the Mechanical Seal Instruction Manual.
If appropriate this is attached.

2. Safety and Environment

The safety notes refer to the system supplied. They can never be exclusive, 

and must be used in connection with the relevant safety regulations for the 

machine, auxiliary equipment, plant and sealed product.

2.1 Warning symbols

The following symbols are used in this instruction manual to highlight 

information of particular importance:

 Danger

  Mandatory instructions designed to prevent personal 

injury or extensive damage.

  Warning of electric current 

ATTENTION

  Special instructions or information to avoid damage to 

the system or its surroundings.

NOTE

 

Information for easy installation and efficient operation.

  Environmental note

Compliance is required with any additional warning signs affixed to the system.

2.2 Safety instructions

   ATTENTION

Every working practice that compromises personal safety is to be 

avoided. All safety requirements in this document must be strictly 

adhered to.
In the event of an operating problem, the machinery must be switched off 

immediately and made safe! Problems must be solved promptly.
Ensure suitable protective clothing is used when maintaining the system.
Plan 74 systems are commonly used with dual mechanical seal 

configurations to reduce the hazard potential from flammable, explosive, 

toxic or lethal process fluids. The intermediate, protective barrier gas, in 

certain failure modes, may risk being contaminated by the process fluid. 

During any maintenance operation operators must thus assume they will 

be exposed to the liquid or gaseous properties of the process fluid and 

have suitable protective gloves, clothing, respirators and equipment.
Particular note must be taken of the relevant guidelines for the electrical 

installations.
A slight mechanical seal leakage will occur during normal seal operation. 

Depending on the duty, this leakage can appear as a gas, a liquid or 

a solid. In case of a worn or defective seal the leakage will increase. 

The leakage may be hazardous or toxic, and a safe collection system is 

required.
Surface temperatures above 60°C/140°F should be protected against 

accidental contact.
The equipment sealed by this seal system must be operated within its 

recommended design limits.
Compounds containing PTFE, fluorocarbons and perfluoroelastomers 

should never be burnt as the fumes and residues are highly toxic. If this 

accidentally occurs protective equipment should be worn as hydrofluoric 

acid may be present.
Additional equipment/flanges/joint seals used within the system are to 

be rated for the appropriate electrical and pressure requirements and are 

to be chemically compatible with the barrier gas and process fluid.

• 

During venting or draining of the buffer region it should be piped to a 

vent or reservoir where it can be safely contained or disposed. 

• 

All above according to the local legislation.

• 

For further information and safe operating limits contact John Crane

• 

All periodical maintenance checks have to be in accordance with local 

legislation and rules.

All welding or cutting operations are forbidden without permission from 

John Crane.
If you are in any doubt please contact your local John Crane office for 

further information before proceeding.

2.3 Environmental aspects
2.3.1 Company policy extract

“It is the policy of John Crane to manage its business activities in  

an environmentally responsible manner, comply with all relevant 

laws and regulations, prevent pollution, and continually improve its 

environmental performance, certification to the latest issue of  

ISO 14001 ensures compliance.”

Содержание API PLAN 74

Страница 1: ...ent of an operating problem the machinery must be switched off immediately and made safe Problems must be solved promptly Ensure suitable protective clothing is used when maintaining the system Plan 74 systems are commonly used with dual mechanical seal configurations to reduce the hazard potential from flammable explosive toxic or lethal process fluids The intermediate protective barrier gas in c...

Страница 2: ...hecking for shipment damage the following recommendations should be undertaken to prevent deterioration arising from long term storage Plan 74 system should be replaced in their original packaging and if possible the crate case should be stored away from direct sunlight in a well ventilated building with a hard floor Temperature control is not normally necessary but large temperature fluctuations ...

Страница 3: ...ed connect the barrier gas supply piping to the inlet connection on the Plan 74 control panel and connect the panel outlet connection to the mechanical seal gas barrier in GBI connection Do not open gas supply at this time 5 3 Electrical connections Only authorized and qualified personnel are permitted to carry out work on electrical systems International and local safety regulations must be follo...

Страница 4: ... should be plugged off to prevent ingress of dirt During normal operation the only attention required is to monitor the barrier gas flow Periodic visual checking at least every 48 hours of the pressure flow within the system is recommended If the consumption rate of the barrier gas is low this can result in a phenomenon where the check valve closes fully and does not open again until the pressure ...

Страница 5: ...ifications of the manufacturer This is guaranteed with John Crane spare parts You are advised to stock the most important wear parts on site The following data is necessary for spare part orders John Crane code part number John Crane order ref no Part description Quantity 7 6 Annual maintenance checks Disconnection shall be made by plant person in charge of authorization Before any maintenance ope...

Страница 6: ...nd specifications without prior notice It is dangerous to smoke while handling products made from PTFE Old and new PTFE products must not be incinerated ISO 9001 and ISO14001 Certified details available on request 2021 John Crane 02 22 johncrane com IOM APIPlan74 NorthAmerica United States of America Tel 1 847 967 2400 Europe United Kingdom Tel 44 1753 224000 Latin America Brazil Tel 55 11 3371 25...

Отзывы: