Pedal contact calibration
Perform a pedal contact calibration after installing or moving an organ.
First activate one or more pedal stops, make sure the organ produces sound.
1.
Check if pedal board is thightly pressed against the organ and the organ
stands on a stable, horizontal surface. Check if each pedal key produces sound
at the desired key depth. Follow steps below when the pedal board appears
un-even or partially not functioning:
2.
Remove the organ bench and slide the pedal board away from the the organ.
It may be necessary to lean the organ slightly backwards to do this.
3.
Now the pedal position set screws on both sides of the organ are visible, see
image below. These set screws are to adjust the pedal key depth.
Image LiVE III AGO - set screws are to adjust the pedal key depth
Loosen the set screws a little to adjust the positions a little upwards, or
downwards. This moves the magnetically sensitive pedal contact position
relative to the pedal key magnets of the pedal board. Tighten the set screws
at the new pedal key depth position – and remember the set positions.
4.
Lean the organ slightly backward to slide the pedal board against the organ
and set the organ upright afterwards.
5.
If you want, place the organ bench over the pedal board.
6.
Repeat step 1 to check the difference and repeat steps 2 to 6 when further
improvement is needed.
Switch on
Switch on the organ with the on/off switch at the right,
underneath the manuals. Wait several seconds. Starting the
control functions and the settings will take some time.
The lights of standard set functions light up. The settings
appear on the display.
Utrecht, Bätz
Location Organ Console
───────────────────────────
Mem : 1 █
█
Trans : 0 █
█
Tune : 431Hz █
█
Temp : Original █
█
Cresc : Off I/II/Pd III
Содержание LiVE III AGO
Страница 1: ...USER MANUAL LiVE III AGO...
Страница 49: ...User Manual LiVE III AGO 50...
Страница 50: ...User Manual LiVE III AGO 51...
Страница 51: ...User Manual LiVE III AGO 52...
Страница 52: ...User Manual LiVE III AGO 53...