Joerns Dolphin Fluid Immersion Simulation System Скачать руководство пользователя страница 5

5

Joerns® Advanced Support Surfaces

Dolphin Fluid Immersion Simulation® Systems

© 2014 Joerns Healthcare • 6110109 RevG • 14-2640

The Dolphin Pediatric FIS System is designed as a 

therapeutic mattress system for a specialty population 

weighing between 5 and 300 pounds (2.3 kg to 136 

kg).¹ 

The Dolphin FIS Stretcher Pad is designed for patients 

weighing up to 700 pounds (318.1 Kg).

2

The Dolphin Wheelchair Cushion System is designed 

for patients weighing up to 250 pounds (113.6 Kg).

3

Warning:

 The risk of entrapment can arise when 

equipment is placed on bed frames that leave gaps of 

even a few inches between the therapy mattress and 

the head panel, foot panel, and bed or side rails. The 

equipment is NOT to be used when such gaps are 

present. See “Important Precautions” section of this 

manual.

Joerns’ Dolphin System is suitable for the treatment 

and prevention of all stages of pressure ulcers, for 

patients who have been assessed to be at risk for 

pressure ulcers, the complications of immobility and 

for patients with healing grafts and flap sites. 

The Dolphin FIS System is quiet, comfortable and 

simple enough for single caregiver installation and 

operation. As the Dolphin System is self-monitoring, 

there is no need for direct intervention or manual entry 

to adjust comfort settings. The system allows manual 

adjustment of the comfort setting to accommodate 

patient preference. After manual adjustment, the 

Dolphin AutoVector Control Module will optimize the 

immersion profile automatically at the new comfort 

setting. 

Additionally, the low friction surface materials coupled 

with the shear-reducing aspects of the FIS technology 

result in a surface system that effectively manages 

both vertical and horizontal shear forces, allowing the 

Dolphin FIS System to meet the comfort and clinical 

requirements of your patients up to 1,000 lbs. (454.5 

Kg),

1

 700 lbs. (318.1 Kg),

250 lbs. (113.6 Kg).

3

We have ensured that the Dolphin FIS System 

addresses the three key areas in the treatment of 

compromised skin: pressure redistribution, reduction in 

friction and reduction in shearing forces.

Introduction

The Dolphin Fluid Immersion Simulation

®

 (FIS) 

System is an advanced therapy system designed 

to provide state-of-the-art pressure redistribution by 

simulating the effects of a body immersed in a fluid 

medium. The Dolphin System includes three key 

components: proprietary software containing the 

Dolphin FIS protocols, a microprocessor-containing 

Dolphin AutoVector

®

 control module, and the Dolphin 

advanced support surface.

The Dolphin System automatically measures the 

specific anthropometric characteristics of the individual 

patient as they engage the support surface. Based 

on active feedback measurements, the Dolphin 

AutoVector control module monitors the support 

surface more than 100 times per second for any 

patient movement or surface changes. The system’s 

software integrates this specific weight and body 

contour data and directs automatic adjustments to 

maintain an optimized three-dimensional support 

surface environment. The result is an individualized 

immersion profile, based on specific patient 

measurements and movements, that creates a near 

neutrally buoyant state on the support surface.

The Dolphin FIS System delivers many of the best 

elements of air-fluidized therapy such as three-

dimensional volumetric engagement and the 

elimination of gradient shear forces, leading to positive 

outcomes for flaps, grafts, and pressure ulcers. The 

Dolphin technology provides minimal distortion to the 

body, while maintaining the normal orientation of bone, 

muscle, and subcutaneous tissue. The Dolphin FIS 

System has been demonstrated to reduce the risk of 

pressure ulcer formation as part of protocols for the 

prevention and treatment of pressure ulcers. 

The Dolphin FIS System is designed as a therapeutic 

mattress system for patients weighing up to  

1,000 pounds (454.5 Kg).

1

 It is customizable to fit bed 

frames, including bariatric bed frames, up to 48 inches 

(122 cm) wide.

1

Mattress weight capacity only; total weight must not exceed bed 

frame manufacturers’ specified load capacity, and when paired with 
an appropriate surface.

2

Stretcher surface weight capacity only; total weight must not exceed 

stretcher manufacturers’ specified load capacity, and when paired 
with an appropriate surface.

3

Wheelchair cushion weight capacity only; total weight must not 

exceed wheelchair manufacturers’ specified load capacity, and when 
paired with an appropriate surface.

Содержание Dolphin Fluid Immersion Simulation System

Страница 1: ...dvanced Surfaces Dolphin Fluid Immersion Simulation System Dolphin Pediatric Fluid Immersion Simulation System To avoid injury read user s manual before using Representative image of the Dolphin Fluid...

Страница 2: ...y within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Danger Explosion Hazard Do not use in the presence of flamma...

Страница 3: ...for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed components often directly assembled by the healthcare facility rath...

Страница 4: ...pecialty Surface Wheelchair Cushion Troubleshooting 12 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Control Nursing Procedures 12 13 Recommended Linen Changing the The...

Страница 5: ...on FIS System is an advanced therapy system designed to provide state of the art pressure redistribution by simulating the effects of a body immersed in a fluid medium The Dolphin System includes thre...

Страница 6: ...bution technology designed to alleviate vertical shear forces The therapy mattresses and specialty surfaces conform to the specific shape of the patient minimizing soft tissue distortion reducing isch...

Страница 7: ...ess that can fit any healthcare bed frame including bariatric frames up to 48 122 cm wide Conforms to specific shape of the patient minimizing soft tissue distortion reducing ischial tuberosity penetr...

Страница 8: ...battery back up will provide power for continued therapy mattress system operation for approximately 12 hours Keyboard Functions Warning For important precautions see page two Caution The patient s he...

Страница 9: ...d from further adjustments When locked pressing the Lock button again restores normal operation and the yellow LED is extinguished Battery Indicators Figure 4 The Battery indicator will blink when the...

Страница 10: ...0 LED s and cover the full control range from Soft to Firm When operating within normal parameters the Auto Feedback LED scale will be amber Should the system be outside of normal parameters the LED s...

Страница 11: ...e appropriate position based on the patient s clinical condition 2 Select the highest or most firm Comfort Adjust setting 3 Hand Check Place a hand with three 3 fingers if head of bed at 30 or higher...

Страница 12: ...g on Battery Back up Ensure that the power is not on Standby If on Standby press the Power button Ensure that all air cells are connected Ensure that the Mode is in the appropriate position for the at...

Страница 13: ...that the patient is positioned properly within the confines of the bed or other specialty item Do not let any extremities protrude over the side or between the bed rails when the mattress is being use...

Страница 14: ...he therapy mattress or specialty surface deflated thoroughly wipe down entire mattress as air cells will lie flat Be sure to reach all areas underneath and in between air cells Allow to air dry If dus...

Страница 15: ...retcher Pad Maximum weight capacity2 700 lbs 318 1 Kg Wheelchair Cushion Maximum weight capacity3 250 lbs 113 6 Kg Pediatric System Minimum weight capacity1 5 lbs 2 3 Kg Dimensions Control Unit 11 5 2...

Страница 16: ...should be observed to verify normal operation in the configuration in which it will be used Guidance and Manufacturer s Declaration Electromagnetic Emissions The AutoVector Fluid Immersion Simulator...

Страница 17: ...ospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital env...

Страница 18: ...ation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference...

Страница 19: ...ng to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz...

Страница 20: ...e Improper maintenance handling and or cleaning Failure to use in the manner indicated in the Dolphin FIS System user manual Any modification repair or alteration done to the Dolphin FIS System that w...

Отзывы: