background image

Joerns Healthcare Ltd
Drakes Broughton Business Park
Worcester Road, Drakes Broughton
Pershore, Worcestershire
WR10 2AG, United Kingdom
(T) +44 (0)844 811 1156
(F) +44 (0)844 811 1157
[email protected]

© 2017, Joerns Healthcare • 374-10045 Rev D • DCO17-0025

Содержание OXFORD DIPPER

Страница 1: ...User Instruction Manual Oxford Dipper To avoid injury read user manual prior to use...

Страница 2: ...se Socket 7 5 B C Socket Illustration 8 6 Assembly and Commissioning Instructions 9 7 Fitting a Ranger Chair to a Dipper Lift 10 8 Safety Precautions 11 9 Operating Instructions 13 10 Daily Check List...

Страница 3: ...ish Oxford Dipper 1 Oxford Dipper Lift Illustration 360 ROTATION OF MAST 1482 mm 2108 mm 1422 mm 311 mm 230 mm A B Socket 1226 mm BOTTOM OF CHAIR HIGHEST POSN 883mm ABOVE FLOOR LOWEST POSN 914mm BELOW...

Страница 4: ...ipper without fully understanding this manual Unauthorised modifications on any Oxford Dipper equipment may affect its safety Joerns Healthcare will not be held responsible for any accidents incidents...

Страница 5: ...ubject to the use maintenance testing and cleaning procedures stated in this manual Due to the hostile environments this product operates in the maximum service life is set at seven 7 years Use beyond...

Страница 6: ...6 English Oxford Dipper 3 A Socket Fitting...

Страница 7: ...diameter core bored into the concrete slab to a depth of 245mm The socket is held firmly in place with a non shrinking cement The construction of the A socket is shown on page 5 When correctly fitted...

Страница 8: ...8 English Oxford Dipper 5 B and C Socket Illustration...

Страница 9: ...carton taking care to protect the finish from damage 3 Insert the spigot at the base of the mast into the socket The spigot will displace any water in the socket so caution should be exercised to avo...

Страница 10: ...ise and check the boom descends NOTE The release valve is fully open and encounters a positive end stop in less than two full turns of the knob DO NOT force the valve past the end stop as this will re...

Страница 11: ...ting operations according to the instructions in the user manual NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift NEVER force an operating or safety c...

Страница 12: ...y cautionary or instruction labels that are illegible should be replaced To avoid the risk of injuries attributed to the use of inadequate replacement parts Joerns Healthcare strongly advises and warn...

Страница 13: ...yond the upper or lower stops If it is necessary to raise the boom to its maximum highest position once maximum position is reached stop pumping the handle immediately or damage may be caused to the h...

Страница 14: ...anger chassis and lower the seat until the chair is reconnected 8 Release the latch from the chair support arm The Ranger seat can now be wheeled away 9 Slings The selected sling is attached to the sp...

Страница 15: ...itted is free to rotate CHECK the spreader bar or chair support tube is firmly attached to the boom and the safety latch holding the spreader bar or chair support tube to the boom is engaged and worki...

Страница 16: ...T TUBE Confirm the chair support tube is free to rotate but can be prevented from rotating by tightening the support tube clamp screw Confirm correct operation of the safety latch securing the tube to...

Страница 17: ...Base of Seat Above Floor Level 914mm C SOCKET Height Boom Lowered 1572mm Height Boom Full Elevation 2258mm Base of Seat Above Floor Level 1033mm Base of Seat Below Floor Level 764mm WEIGHTS Mast Asse...

Страница 18: ...g Special requirement slings can be made to customers own specification consult your dealer for details NOTE For detailed fitting instructions please refer to the user guide supplied with each sling W...

Страница 19: ...so they can be contacted should any problem arise If you are in any doubt as to where your lift was purchased Joerns Healthcare can trace the supplier if you quote the serial number of the lift All wa...

Страница 20: ...d Drakes Broughton Business Park Worcester Road Drakes Broughton Pershore Worcestershire WR10 2AG United Kingdom T 44 0 844 811 1156 F 44 0 844 811 1157 info joerns co uk 2017 Joerns Healthcare 374 10...

Отзывы: