Страница 1: ...TOR CT1900 Ref no QS2500I ORIGINAL INSTRUCTIONS Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0JU U K Read and understand the user and safety instructions before you use...

Страница 2: ...rculation by us In case of alteration of the machine not agreed upon by us this declaration will lose its validity Product description Petrol Generator Model CT1900 Ref no QS2500I Appropriate EC direc...

Страница 3: ...poses a risk and can lead to serious damage and or injury Disconnect the generator before carrying out any kind of maintenance Let the engine reach full speed before connecting a power consuming load...

Страница 4: ...on it s side as oil or fuel may leak and damage the generator or your property If the generator has been used always allow it to cool for at least 30 minutes before transporting the generator and ensu...

Страница 5: ...ng when the engine is working Refueling the generator when it is working will cause a fire e Be sure wipe out the spilling oil for afraid of Fire Spilling oil will increase the risk of fire Fire hazar...

Страница 6: ...re poisonous Do not inhale Exhaust fumes contain carbon monoxide Carbon monoxide can be extremely dangerous or even fatal Never run the generator indoors Only operate the machine in well ventilated ar...

Страница 7: ...ainty K 96 dB A K 3 dB A Guaranteed sound power level Lwd 95dB A Protection class I Protection against moisture IP23M Max ambient temperture 40 C Proper use The device is designed for applications ope...

Страница 8: ...generator to the power supply socket outlet Keep the cable length to the consumer as short as possible 2 Environmental protection Dispose of soiled maintenance material and operating materials at the...

Страница 9: ...r Connect the equipment you want to use to the 230 V and 115V sockets 3 Important These sockets may be loaded continuously S1 with 2600W and temporarily S2 for a maximum of 2 minutes with 2800W The ge...

Страница 10: ...10 TECHNICAL DESCRIPTION 1 Petrol gauge 7 115V socket 2 Fuel tank 8 230V socket 3 Fuel tank cap 9 12V DC outlet 4 Air filter 10 Voltmeter 5 Recoil starter 11 AC circuit breakers 6 Main engine switch...

Страница 11: ...eck the generator Uncover the oil mouth then clean the engine oil ruler with clean cloth Plug the engine oil ruler into the oil mouth and don t turn it If the oil level is below the lower limit of the...

Страница 12: ...12 Level of fuel Uncover the fuel tank Check the fuel level if the fuel level is low you should add more Add the fuel to the shoulder part of fuel filter Fix the fuel cap...

Страница 13: ...Remove any load off the alternating current socket and turn off the alternating current circuit breaker NOTE In most cases operating the generator with both the 240V AC and the 12V DC at the same time...

Страница 14: ...CHOKE position Turn the switch of engine to ON position Pull the starting handle slightly until you feel some resistance then put forth your strength to pull it When the temperature of engine increase...

Страница 15: ...on Please follow the rules Avoid improper operation make sure to make your generator ground connection Electrical equipments esp motor driven devices will produce lots of electric current when they st...

Страница 16: ...igh electric current to low electric current successively Notice When you want to connect the generator to the family power you should ask electricians to fix it After connecting the load to the gener...

Страница 17: ...17 Use of Alternating Current Start engine procedure before start engine such as 1 Fuel valve turn to ON 2 Switch of engine turn to ON Connect devices All right All right Forbid...

Страница 18: ...reaker or connect the DC circuit break 4 Stop engine Turn off the alternating current circuit breaker Turn off the switch of engine Turn off valve Notice If you want to stop engine emergently please t...

Страница 19: ...ke sure the area is well ventilated Periodic maintenance and adjustment is necessary to keep the generator in good operating condition Perform the service and inspection at the intervals shown in the...

Страница 20: ...20 Change engine oil Uncover the oil mouth Turn off the spiral plug to eliminate the engine oil Fix the spiral plug Add the engine oil to the upper limit of engine oil ruler...

Страница 21: ...21 Fix the engine oil plug ruler Air filter the same as page13 Sparking plug Remove the sparking plug cap Remove the sparking plug Get rid of the accumulated carbon...

Страница 22: ...ix the sparking plug and sparking plug cap Maintenance of fuel filter Turn the fuel level to OFF position and remove fuel filter cup Remove the filter Blow from the counter director of arrow with an a...

Страница 23: ...er spacer and fuel filter cup 6 Storage turn off the fuel valve Screw off fuel filer cup pour off all the fuel in the cup Doesn t drain direct to the ground please to the container and fill into bottl...

Страница 24: ...lace the gasket and screw the cup on tightly Remove drain plug and drain off all the fuel from carburetor Remove oil drain plug drain off all the oil 6 Reinstall the drain plug 7 Add oil to the upper...

Страница 25: ...25 8 Pull starter handle slightly until resistance itself 7 Trouble shooting Engine won t start If the engine switch is turn to ON Check oil...

Страница 26: ...26 Check fuel Remove spark plug Check spark plug OK...

Страница 27: ...27 Check the buld Check the ac switch OK 115V 230V...

Страница 28: ...e food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge Thi...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...31 CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China...