In the case of an error the LCD shows ”E1”.    If this happens, the thermostatic heating sytem will NOT 

be available, the heater doesn’t work.

 

15

Operating the Air Blower

 

Press

  controls the blower

 

16

Fahrenheit & Celsius Temperature shift

 

In the status of

Power off

  pressing the key

 

  can change the mode of 

Fahrenheit & Celsius degree   

17

When there is no water in the spa. All surfing pumps, blower and heating system can not start up. However 

the corresponding signals will flash on the LCD. 

18

Prevent freezing function:

 

The heater & circulation pump will work automatically once the water temperature is below 

5℃, when the water 

temperature is reach at 10℃, heating will stop. This function is only available while the spa is on 

normal power supply.

 

 

IV

Electric parameters

 

1

Performance index

 

Rated voltage

  220V/50Hz                                               

Maximum working current

60 A/220

V-240V~

 

Voltage-resistance

1250V/1

 minute without penetration

         

Isolative resistance

:》

10M

Ω

 

Water resistance grade

IPX5                                                         

Electric shock resistance

first grade 

 

(2) Output loading index 

Heater

 AC220V/3KW x 1                          Surf Water pump

  AC220V/3 HP x2 

water pump

 

 AC220V/2H

P x2                                          pump

AC220v/1HP x 1 

Air pump

  AC220V/0.7kw x 1     

spa light

  AC12V/5W x 1                                                  Ozone

Ozone

 220

V—240V

/100

W×1 

water Radio

1) Frequency Range

 FM

 87.0~108.0MHz 

                2) Maximum Output Power

 10W 

3) Speaker

8

Ω

damp proof speaker 

 

 

5.Warning Information

 

 

a.

       

Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

 

b.

       

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

 

c.

       

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety.

 

d.

       

Children should be supervised to ensure that they do not play with the appliance.

 

e.

       

Details concerning cleaning and other maintenance

 

f.

 

Maintenance of water purity, especially PH values and chlorine concentrations.

 

g.

       

Cleaning and disinfection

 

h.

       

Use and installation of a cover.

 

Содержание SPA-8098

Страница 1: ...1 HOT TUB Model SPA 8098 OPERATING INSTRUCTION ...

Страница 2: ...g On off Surfing pump circulaltion pump On off Set Circulation Cleaning Time Heating On off Set Pre heating Set Temperature Note The functions listed with bule letters only works on the condition of on off II Function Summary 1 Max with 6 KW heating system set pre heating set and display temperature 2 Max with 3 surfing pumps 1circultion pump view pump and 1 blower 3 Set Ozone Set Spa lights 4 CD ...

Страница 3: ...n cleaning function is off 2 Lock memory Mode optional function The memory lock will start work by pressing MEM key in the status of power off when the spa has not been adjusted for a period of 30 minutes When the memory locked key is pressed TWICE MEM the spa will become unlocked and the word LOCKED will disappear 3 Adjusting Time In the status Power off and the pre heating and circulation cleani...

Страница 4: ...ning setting mode and the LCD showes and flashes and then the circulation workes on Press again to off the circulation cleaning and the will disappear 2 Press minutes and hours to adjust the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stopping The adjustment range is 0 59 It will add 1 hour when pressing HOUR ea...

Страница 5: ... this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key to clear settings and exit Notice 1 All the setting of Circulation cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning 5 Set preheating if required Only one pre h...

Страница 6: ...s and enter Pre heating setting mode and the LCD flashes of ON Press can turn on the pre heating setting and pressing again will turn off the pre heating ON OFF on LCD will show ON and will not flash Press to turn off pre heating The LCD will show OFF without flashing When the system enters into pre heating mode the setting time will flash on the LCD this time is the pre heating time at this momen...

Страница 7: ...When everything is set correctly press the to confirm the system will quit the pre heating setting mode Notice 1 All setting of preheating must be in Power OFF mode just turn on the spa the LCD will display 2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time of pre heating is as same as current time the heater will start working off means the heater...

Страница 8: ...on to Power ON OFF Pressing the key in power off status to enter the power on status To pressing the in the status of power on to enter the power off status The LCD screen shows the on or off See following Fig 9 10 AM OFF AM OFF Fig 9 OFF Fig 10 ON 9 Temperature setting In the status of Power on and HEATER is working It will add 1 centigrade by press each time the temperature will be added continu...

Страница 9: ...d circulation is about to start 12 Operation of lasting circulation cleaning Press the key at any time to turn on or off the lasting circulation cleaning work mode is like the preset circulation cleaning The surfing pumps and blower work for 30 seconds at every 30 minutes Ozonizer works at every 15 minutes Once any surfing pumps or blower start the ozonizer without working The ozonizer can not wor...

Страница 10: ...esistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 3 HP x2 water pump AC220V 2HP x2 pump AC220v 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 1 Ozone Ozone 220V 240V 100W 1 water Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker 5 Warning Information a Means for disconnection must be incorporated in th...

Страница 11: ...CTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed by a qualified service representative and ground 3 FOR YOUR SAFETY This product should be installed by a professional service technician qualified in hydrotherapy bath installation 4 lt s prohibited to cover the instrument with something while opeating 5 when u...

Страница 12: ...ange a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be nundated by water 1 Connect the temperature detector 2 Change a new temperature detector being incapable of activate water pump and water pump icon flashing 1 water...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Отзывы: