background image

 

 

7

pressing the 

HOUR

 without stop

The adjustment range is 

AM 0~PM 11

 

And after time setting of pre-heating, you could go on to next step

 

3

   Press 

SET

VOL+

to continual time setting of pre-heating

  it will show the minimum continue time is 10 

minutes on the LCD

  and this time will not flash

  It will add 10 minutes by pressing 

MIN

 each time

and it will add 1 hour when pressing 

HOUR

each time

  please note that the maximum of continual time 

is 19 hours and 50 minutes

  When you set up well of the continual time 

  you could go on to the next step

 

4

 Press 

SET

VOL+

  again to the temperature setting of pre-heating

 It will show

 SET

  label on the LCD 

panel

 press 

TEMP

and    button could change the temperature setting

The range of temperature 

setting is  25~45

℃。

 

5

 When everything is setting well

Press

HEAT

again

  the system will quit the pre-heating setting status. 

 

***

 

Notice

 *** 

1

 all setting of pre-heating must be in Power OFF status, just connect the spa with 
the power supply. and the LCD display 

---

”。

 

2

 please note that it shows "on" or "off" on the LCD, "on" means pre-heating is   
turn on, when the    time of pre-heating is the same as currently time, the heater 
will start working. "off" means the heater can't start-up anytime

 

3

 Circulation PUMP and HEATER are not working while all setting time

 

 

 (6) Pre-heating

 

When the time of real time and pre-heating time is consistent

 meanwhile

  there is water in the bathtub 

and the pre-heating button is

on

  the system will start the pre-heating and circulation pump and auto-constant 

temperature system will work at the same time

  Then LCD will show count down time 

the two middle spot will 

not flash any longer

 and corresponding working status

  In the pre-heating process

 till cont down time 

finished

 the pre-heating will be turned off automatically by system or by pressing the

HEAT

 or 

ON/OFF

 key intentionally

 

***

 

Notice

 *** 

1

 

When setting temperature is lower or equal water temperature

Even the 

Pre-heating is working but the circulation PUMP and HEATER are not 
working

 

2

 

When the HEATER is 

I

frame

The power of circulation PUMP must 

reach or higher 750W

 

3

 

Answer for condition of 

2

and the HEATER is not working

Please 

short the line of water press switch

 

 

(7)circulation-cleaning: 

When the time of real time and pre-heating time is consistent, meanwhile, there is water in the bathtub and 

the circulation-cleaning button is

on

  the system will start the circulation-cleaning

  and the circulation pump 

and ozone(If it is on) will work at the same time

 Then LCD will show count down time

 In the 

circulation-cleaning process

  till cont down time finished the circulation-cleaning will be turned off automatically 

Содержание SPA-8028

Страница 1: ...1 Outdoor spa SPA 8028 PROGRAMMING INSTRUCTIONS ...

Страница 2: ...Hour CD RADIO Radio CD Input On Off SET VOL Volume up Set switch C F Blower on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater...

Страница 3: ... halt and the LCD will show the present time and temperature It will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is power off so as well as the pre heat and circulation cleaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in th...

Страница 4: ...P3 and enter to Circulation cleaning setting status and the LCD flashes of 2 Press OPEN can turn on Circulation cleaning setting status by opposite if press CLOSE it will turn off the Circulation cleaning And this time on LCD will not flash When the system enter into time setting of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will st...

Страница 5: ... When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to turn on or off OZONE synchronization OZONE of LCD will flash This is mean OZONE is turned off synchronization Press OZONE can turn on OZONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circu...

Страница 6: ...ite if press CLOSE it will turn off the pre heating and at this time ONOFF on LCD will turn to ON and will not flash if press CLOSE to turn off pre heating LCD will display OFF which do not flash there When the system enter into time setting of pre heating the setting time will flash on the LCD this time is the pre heating time which will start at this moment only MIN and HOUR are available to cha...

Страница 7: ...on PUMP and HEATER are not working while all setting time 6 Pre heating When the time of real time and pre heating time is consistent meanwhile there is water in the bathtub and the pre heating button is on the system will start the pre heating and circulation pump and auto constant temperature system will work at the same time Then LCD will show count down time the two middle spot will not flash ...

Страница 8: ...cy form channel 3 to the present Searching channel Ⅰ Key AUDIO CD is the ON OFF key for radio and CD and it is only available in the status of power on The first pressing is turning on the radio the second pressing will turn off the radio and turn on the CD at the same time and the third will turn off the radio and CD simultaneous Ⅱ LCD will show present frequency and volume of the radio after tur...

Страница 9: ...constant temperature heating system 2 After the startup of constant temperature heating circulation pump will be running all the while 3 For example if the temperature is set at 35 when the water temperature reaches or exceeds 36 the heater will be turned off automatically and the circulation pump will stop after 5 second If PUMP3 is turn off However when the water temperature reach or lower than ...

Страница 10: ...e 200MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 2 HP x 3 water pump AC220V 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 2 Ozone AC12V 15W x 1 water pump AC220v 0 25HP x 1 Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker ...

Страница 11: ...11 ...

Страница 12: ...12 ...

Страница 13: ...OM ACN ACN ACN P2 P3L P3 NO COM NC NO COM PUMP3 PUMP2 P12 HEAT ACN ACN ACN P11 220VAC NC NO COM COM NO NC COM NO NC PUMP3L BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP3 Circulation CONNECTION FACE PUMP2 DVD ACN ACL HEAT PUMP11 MAIN BOARD ...