2

PROGRAMMING INSTRUCTIONS 

 

   

1.  Illustration to buttons 

F

AM

PM

LIGHT

OZONE

OFF

ON

PUMP2

BLOWER

PUMP1

PUMP3

SET

LOCKED

HEAT

C

F/

OZONE

PUMP2

HEAT

PUMP3

ON/OFF

CD

MEM

CLOSE

HOUR

OPEN

MIN

SET

VOL+

TEMP

 

Fig

1

Sketch map of big massage bathtub 

 

 

 

MIN

  Frequency up- searching / Minute

ON/OFF

On/ Off 

HOUR

Frequency down- searching/ Hour 

CD

RADIO

Radio & CD Input On/ Off 

SET

VOL+

Volume up/ Set switch   

C

F/

Blower on/ Off & Temperature Mode 

Shift 

OPEN

Volume down/ Open   

Light from the bottom on/ Off 

MEM

Radio memory/ Lock 

Surf Water pump 1    on/ Off 

CLOSE

  Radio searching / Close 

PUMP2

  Surf Water pump 1    on/ Off 

OZONE

 Circulation cleaning set of ozone/ 

On/Off 

PUMP3

  Setting Of circulation Cleaning & Surf 

Water pump 3    on/ Off. 

HEAT

 Preheat  setting & Heater On/ Off 

TEMP

 Temperature setting 

Note

 

.Function of buttons with blue parts only works under the 

U

power-off status

 
   
 
 
 

Содержание SPA-8028

Страница 1: ...1 Outdoor spa SPA 8028 PROGRAMMING INSTRUCTIONS ...

Страница 2: ...Hour CD RADIO Radio CD Input On Off SET VOL Volume up Set switch C F Blower on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater...

Страница 3: ... halt and the LCD will show the present time and temperature It will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is power off so as well as the pre heat and circulation cleaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in th...

Страница 4: ...P3 and enter to Circulation cleaning setting status and the LCD flashes of 2 Press OPEN can turn on Circulation cleaning setting status by opposite if press CLOSE it will turn off the Circulation cleaning And this time on LCD will not flash When the system enter into time setting of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will st...

Страница 5: ... When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to turn on or off OZONE synchronization OZONE of LCD will flash This is mean OZONE is turned off synchronization Press OZONE can turn on OZONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circu...

Страница 6: ...ite if press CLOSE it will turn off the pre heating and at this time ONOFF on LCD will turn to ON and will not flash if press CLOSE to turn off pre heating LCD will display OFF which do not flash there When the system enter into time setting of pre heating the setting time will flash on the LCD this time is the pre heating time which will start at this moment only MIN and HOUR are available to cha...

Страница 7: ...on PUMP and HEATER are not working while all setting time 6 Pre heating When the time of real time and pre heating time is consistent meanwhile there is water in the bathtub and the pre heating button is on the system will start the pre heating and circulation pump and auto constant temperature system will work at the same time Then LCD will show count down time the two middle spot will not flash ...

Страница 8: ...cy form channel 3 to the present Searching channel Ⅰ Key AUDIO CD is the ON OFF key for radio and CD and it is only available in the status of power on The first pressing is turning on the radio the second pressing will turn off the radio and turn on the CD at the same time and the third will turn off the radio and CD simultaneous Ⅱ LCD will show present frequency and volume of the radio after tur...

Страница 9: ...constant temperature heating system 2 After the startup of constant temperature heating circulation pump will be running all the while 3 For example if the temperature is set at 35 when the water temperature reaches or exceeds 36 the heater will be turned off automatically and the circulation pump will stop after 5 second If PUMP3 is turn off However when the water temperature reach or lower than ...

Страница 10: ...e 200MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 2 HP x 3 water pump AC220V 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 2 Ozone AC12V 15W x 1 water pump AC220v 0 25HP x 1 Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker ...

Страница 11: ...11 ...

Страница 12: ...12 ...

Страница 13: ...OM ACN ACN ACN P2 P3L P3 NO COM NC NO COM PUMP3 PUMP2 P12 HEAT ACN ACN ACN P11 220VAC NC NO COM COM NO NC COM NO NC PUMP3L BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP3 Circulation CONNECTION FACE PUMP2 DVD ACN ACL HEAT PUMP11 MAIN BOARD ...