4
FOUNTAIN ASSEMBLY INSTRUCTIONS
FOUNTAIN COMPONENTS
1. Top Hat
– Fits on top of the centre column and holds the metal screw in the middle.
2. Tiers
– 3 different sizes, slides down the centre column to rest into place.
a.) Small Tier (Top)
b.) Medium Tier (Middle)
c.) Large Tier (Bottom)
d.) Extension Tier (Smallest), supplied with 5” extension; purchased separately.
3. 5” Extension Piece. You have to purchase this separately,
4. Centre Column extension
– Rests on top of the centre column. Where the middle & top
tiers sits.
5. Centre Column
– Rests within the centre housing in the middle of the basin.
6. Auger Extension
- Sits on top of the metal screw inside the centre column extension.
7. Auger
– Sits on the square metal shaft in the middle of the basin inside the centre
column.
8. Centre Housing
– Supports centre column. Fixed to fountain basin.
9. Removable Basin (not including SQ1)
– Which sits on top of the drum and holds the
centre column and screw. Do not place it in the dish washer.
10. Drum
– This is the bottom of the fountain.It houses all of the electrical components,
including the motor unit. Only to be opened by a qualified person.
a.) The vent holes allow hot air produced by the motor and heating elements to
escape, cooling the electrical components. Vent holes should not be covred during
use
11. Membrane Switch (SQ1)
– The control panel system maintains heater temperature to
between 45 to 55 degrees Centigrade and switches the motor on and off as required.
The Heater on the SQ1 is preset and you cannot change the temperature There are
3 LED indicators. The Heater light comes on when you switch on the fountain and it
will stay on until the temperature reaches 55 degrees and it will go off as the control
panel cuts off the heater and it will comes on again when the temperature reaches 45
Degrees. This cycle will continue till you switch off the switch. The motor light will come
on when the motor is switched on. Please note the motor will only turn on once the
Indictor stops flashing. The membrane switch panel has a push-button command the
ON/OFF state of the motor.
Membrane Switch (SQ2 & SQ3)
– The control system switches the chocolate heater
on and off to maintain the temperature at a pre-set level, and switches the motor
on and off as required. There is a two digit LED display to indicate the temperature
in degrees Centigrade, and also two individual LED indicators which light when the
heater and motor respectively are ON. The membrane switch panel has a pair of push-
button switches for UP and DOWN control of the temperature, and a third push-button
commands the ON/OFF state of the motor.
12. Fuse
– The machine has 3 fuses. 1st fuse is in the power cord. 2nd fuse is in the power
socket on the drum and the 3rd fuse is on the PCB board inside the drum. Only a
qualified electrician should replace the fuse in the PCB board.
13. Adjustable Feet
– Screw into the bottom of the base. These may be tightened
or loosened to raise or lower a particular side of the fountain for leveling.
Содержание SQ1