8
6.
INSTALLATION STANDARDS
Must use two clamps fix the fixture, and tighten the clamps with1/4 lock, only fully clockwise
rotate 90 °then can lock the fasteners. Add one safety insurance rope on the hole of light base. pls
attention not connect to the transport handle.
Attention! One product only can accept one input one
output.
DMX512 cable must use the professional shielded twisted pair cable; standard loudspeaker
cable is not reliable to control the long-range data. 24AWG cable is suitable for more than 300
meters long-distance signal transmission and must add\ DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection to branch,
DMX512 splitter is necessary.
If use the DMX512 splitter. At first connect DMX512 Splitter input terminal to controller .And
then connected from the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with terminal insertion
6.1 Equipment fixation
1. Before installation, it is necessary to verify that the gear clamp is not damaged and can
bear at least 10 times the weight of the equipment. The verification building can bear the
weight of at least 10 times the total weight of the equipment and fixture cable attached
equipment.
2. The fixture is mounted on the base of the lamp body, inserts the fastener into the mounting
hole of the base, and holds the handle of the fastener to lock the 1/4 ring clockwise, and the
other fasteners are installed in the same way.
3. Install a safety rope that can withstand 10 times the weight of the equipment.
4
、
Check whether the vertical lock has been opened. There is no combustible or attached in
the verification equipment within 3 meters. Near other flammable objects.
Notice
!
It is necessary to use 2 fixtures to fix the equipment and fasten the fixture with the 1/4 button.
A clockwise rotation of 90 degrees can be used to lock the fastener. Add 1 safety ropes to the
base hole. Be careful not to connect to the handle.
6.2 Device connection
lWarning
!
The signal of a device can not connect two inputs and two outputs.
1) 3 core plug-in connector with DMX input and output. Socket 1 pins are grounded, 2 pins
connect negative polarity signals, and 3 pins connect positive signals.
2) use shielded twisted pair cables specially designed for DMX 512 devices; standard
amplifiers can not reliably control long distance data. 24AWG cable is suitable for use for
more than 300 meters. When long distance signal transmission, DMX 512 signal amplifier
must be added.
3) do not use two outputs to separate connections. If you want to separate the continuous
connection components, you must use the DMX512 divider to separate them. If the DMX512
allocator is used, the controller is connected to the input of the DMX512 distributor first, then
the next device is connected from the output end of the distributor, and the terminal plug is
finally fitted according to the above method.
7. AC POWER