background image

16175-01 rev. A

Page 1

©2019 JMA Wireless. All rights reserved. This document contains proprietary and confidential information. All products, company  names, 
brands, and logos are trademarks™ or registered® trademarks of their respective holders. All specifications are subject to change without 
notice. Revised: January 29, 2020

+1 315.431.7100     [email protected]

Installation Instructions

JMA Weather Protection System™

WPS-DM-14S, DM Connector to Port

Materials 

(all sold separately)

WPS-DF

(for antenna)

WPS-DM-14S

RDCUTTER

TQ-114-F18

torque wrench

Step 1: Install WPS-DM-

14S and 1/4” connector

Prior to cable prep, slide the WPS-
DM-

14S onto the 1/4” cable 6–12” 

from the end.

Prep and install the 1/4” cable to install 
the JMA 1/4” UXP compression 
connector. Refer to the 1/4” corrugated 
connector installation instructions.

Step 2: Cut WPS-DF

Measure the WPS-DF from the end 
of the port to the beginning of the 
threads as shown. Use your thumb to 
mark a cut line.

Align the blade of the RDCUTTER to 
the thumb mark indicating the cut 
length. Using one firm cutting motion, 
cut the WPS-DF to the proper length.

Step 3: Install WPS-DF

Place the cut WPS-DF onto the 
antenna or device female port.

Ensure that the WPS-DF is properly 
placed on the antenna or device port, 
positioned just past the threads. 

Properly measured WPS-DF.

Properly installed WPS-DF.