SECTION 2 - SERVICE PROCEDURE
31215460
2-37
Lithium ION Charge Indicator
The indicator shows the present charge condition of the
Lithium ION battery pack as specified in table below.
Table 2-5. Lithium ION Battery Charge Indicator
Battery Pack
1st Generation
2nd Generation
3rd Generation
38V and 48V Systems
1st phase - recharging with max current available
Red Steady
2nd phase - recharging with reduced current
Red Flashing
3rd phase - Cells under light charge
Yellow
Yellow Flash
Yellow Flash
4th phase - Equalization/standby
Yellow Flash
Yellow
Yellow
72V and 83V Systems
1st phase - recharging with max current available
Red Steady
-
2rd phase - Cells under light charge
Orange Flash
-
3th phase - Equalization/standby
Green Steady
-
76V Systems
1st phase - recharging with max current available
-
Red Steady
2rd phase - Equalization/standby
Green Flash
3rd phase - End of charge
Green Steady
38V, 48V and 72V Systems Fault
The battery pack is disconnected (contactor open)
Green/Red Flash
83V Systems Fault
The battery pack is disconnected (contactor open)
-
Green
-