SECTION 2 - SERVICE PROCEDURE
2-6
31215460
BMS Connectors (2nd Generation BMS)
On 2nd Generation BMS, the resistances to discharge the
cells are located on the cage heating area, while 4 temper-
ature sensors are placed on the same section to monitor
the cage temperature. With temperatures above 70°C the
BMS opens the internal battery contact to avoid overheat-
ing.
On the 1st Generation BMS the temperature sensors are
located on the board cards, and the internal battery con-
tact is opened when the temperature reaches 60°C.
MAF11490
48 Volt Battery Pack
Table 2-3. 2nd Generation BMS Connectors
J1, J2, J3 Temperature Sensor Sockets
J6
Voltage cells Measurements Socket
Resistance to discharge the cells during the Equalization phase
J7
Internal contactor and fans
J8
Current sensor socket (LEM)
J9
BMS feed
J10
CAN BUS socket