SECTION 4 - MACHINE OPERATION
3121716
4-13
4.9
INVERTER
The inverter converts 48 VDC to 110 VAC to allow operation of
power tools from the machine’s batteries.
• The inverter is operational when the emergency stop switch is
pulled out.
• The machine and inverter can be operated at the same time.
• The inverter will shut off at approximately 42 VDC and stay off
until the emergency stop switch is recycled. It will operate
again until voltage drops to 42 VDC.
• The machine will operate down to 36 VDC.
• The inverter will shut down if the high temperature light indi-
cated overheating. It will automatically turn back on when
cooled.
• The overload light indicates an output wiring short circuit or a
load that is too large for the rating of the inverter.
4.10
MACHINE FUNCTION SPEEDS
The Function Speed Control affects the speed of boom functions
Lower Lift, Telescope, and Rotate. Turn the control clockwise to
increase function speed or counterclockwise to decrease func-
tion speed. When in the counterclockwise maximum position, all
functions are placed in creep speed.
4.11
MACHINE SAFETY SYSTEM OVERRIDE (MSSO)(CE
ONLY)
The Machine Safety System Override (MSSO) is
used to override function controls for Emergency
Platform Retrieval only. Refer to Section 5.7,
Machine Safety System Override (MSSO)(CE
Only)for operating procedures.
To
order
go
to
Discount-Equipment.com
Содержание E400A Narrow
Страница 28: ...SECTION 1 SAFETY PRECAUTIONS 1 14 3121716 NOTES T o o r d e r g o t o D i s c o u n t E q u i p m e n t c o m...
Страница 97: ...SECTION 4 MACHINE OPERATION 4 36 3121716 NOTES T o o r d e r g o t o D i s c o u n t E q u i p m e n t c o m...
Страница 102: ...SECTION 5 EMERGENCY PROCEDURES 5 4 3121716 NOTES T o o r d e r g o t o D i s c o u n t E q u i p m e n t c o m...
Страница 107: ...SECTION 6 ACCESSORIES 6 4 3121716 NOTES T o o r d e r g o t o D i s c o u n t E q u i p m e n t c o m...
Страница 132: ...T o o r d e r g o t o D i s c o u n t E q u i p m e n t c o m...