SECTION 4 - MACHINE OPERATION
4-4
– JLG Lift –
3121189
6.
When the battery cell voltage reaches 2.37 V/cell the 80%
CHARGE LED will light up. The charger then continues to
monitor the increase in charge until it sees no increase,
and then terminates the charging process.
7.
The CHARGE COMPLETE (100%) LED will light when the
batteries are fully charged.
8.
Unplug the charger AC power cord and stow the cord.
Abnormal Cycle Indicator LED
The ABNORMAL CYCLE indicator LED will light when;
• The AC input to the charger was interrupted.
• There is a dead cell or cells in the battery.
• One or more of the battery connectors are loose or cor-
roded.
Figure 4-3. Dual Voltage Charger - Front Panel.
1.
% of Charge in Progress
LED’s (Green)
2.
Charger On LED (Green)
3.
Abnormal Cycle LED
(Yellow)
4.
Circuit AC Circuit Breakers
5.
AC Voltage Selection
Switch
1
2
3
4
5
Содержание 19AMI
Страница 2: ......
Страница 34: ...SECTION 3 MACHINE CONTROLS AND INDICATORS 3 6 JLG Lift 3121189 This page intentionally left blank...
Страница 46: ...SECTION 4 MACHINE OPERATION 4 12 JLG Lift 3121189 This page intentionally left blank...
Страница 61: ...SECTION 7 GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE 3121189 JLG Lift 7 7 1 2 3...
Страница 66: ......