113374 - 4
Telephone 01422 822282
25
Microprocessor Controller (Computer) Dryer Models
a. Spin and stop times are not adjustable in the Automatic Mode and have been preprogrammed into the
microprocessor controller (computer) for 150-seconds spin time in the forward direction and
120-seconds in the reverse direction with a 5-second dwell (stop) time.
b. Spin and stop times are adjustable in the Manual (timed) Mode.
BASKET (TUMBLER) COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material with a
solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove this coating.
8. Each dryer
should be
operated through one (1) complete cycle to ensure that no further adjustments are necessary
and that
ALL
components are functioning properly.
9. Make a complete operational check of
ALL
operating controls.
Microprocessor Controller (Computer) Programs/Selections...
Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly used
parameter (program) selections. If computer changes are required, refer to the computer programming manual,
which was shipped with the dryer.
K. COMPRESSED AIR REQUIREMENTS
The dryer requires an external supply of compressed air (2.5 cfh [cubic feet per hour] @ 80 psi [0.07 cmh [cubic meters
per hour] @ 5.51 bar]) for gas models. On gas model dryers, compressed air is necessary/required for blower air jet
operation to clean lint from the impellor/fan (squirrel cage).
1. Air Requirements
Microprocessor Controller (Computer) Dryers
Shaded areas are stated in metric equivalents
Compressed
Air Supply
Air Pressure
Normal
80 psi
5.51 bar
Minimum Supply
70 psi
4.82 bar
Maximum Supply
90 psi
6.21 bar
Содержание D90