-2-
(xxx=250-305, in steps of 5, 60 cells)
JKMxxxM-60-BDVP
(xxx=260-315, in steps of 5, 60 cells)
Group 8
JKMxxxM-60H-BDV
JKMxxxM-60H-BDVP
(xxx=250-305, in steps of 5, 60 cells)
Notes:
①
PP: the eagle+ series module
②
DV: photovoltaic Module-eagle dual with 1500V
③
JKMS: the smart series module
④
J: customized product for Japanese market
⑤
BDV:the bifacial N type series module
⑥
BDVP:the bifacial P type series module
⑦
H:Half-cut series module
Make sure the module array is designed in such a way not to exceed the maximum
system voltage of any system component such as connectors or inverters.
The assembly is to be mounted over a fire resistant roof covering rated for the
application. Before mounting the module, please consult your local building
department to determine approved roofing materials.
The modules are qualified for application class A: Hazardous voltage (IEC 61730:
higher than 50V DC; EN 61730: higher than 120V), hazardous power applications
(higher than 240W) where general contact access is anticipated. Modules qualified
for safety through EN IEC 61730-1 and -2 within this application class are considered
to meet the requirements for Safety Class II.
1.3 Warnings
PV modules generate DC electrical energy when exposed to sunlight or other
light sources. Active parts of module such as terminals can result in burns, sparks,
and lethal shock.
Artificially concentrated sunlight shall not be directed on the module or panel.