-8-
Be sure to avoid shadowing effects from the module clamps. When choosing this type
of clamp-mounting method, please be sure to use at least four clamps on each
module, and two clamps should be attached on each long side of the module.
Depending on the local wind and snow loads, if excessive pressure load is expected,
additional clamps or support would be required to ensure the module can bear the
load. The applied torque should be large enough to fix it steadily ( about 16-20 N▪m ) .
For safety, you’d better follow the clamps manufacture’s recommendation. Please
find detailed mounting information in the below illustration, and we suggest the
clamps are mounted between J and K,as shown below.
Type1
Group 1
、
Group 2
、
Group 3
、
Group 4
Mechanical
Load Pressure
Length
Manual direction
Front surface:
≤2400 Pa
Back surface:
≤2400 Pa
120mm
The middle of clamp should be between J and K,
J=300mm,K=400mm, L=1/2 module length
Front surface:
≤5400 Pa
Back surface:
≤2400 Pa
150mm
Screw
Top middle clamp
Bottom end clamp
EPDM
EPDM
Screw
Bottom end clamp
Top end clamp