17
List test page
The meaning of each parameter
List steps:
Set the number of steps in the list, up to 15 steps.
Test mode:
automatic/manual. If you select automatic mode, the instrument will
determine whether to perform list test based on the threshold voltage. If you select manual,
you need to press the OFF function key at the lower right corner of the instrument to
perform list test.
Step mode:
continuous, each step is tested continuously.
Threshold voltage:
When the test mode is automatic, this setting is the basis for starting
the test. If the connected battery voltage reaches the set voltage, the instrument will
automatically perform a list test.
Step X:
For each step of parameter setting, press the up and down keys to move the
cursor to this option, and use the function keys to select the parameter to be set to
complete the setting; optional steps are: discharge, charge, overcurrent, overcharge,
overdischarge , NTC, static, use the
more
key to turn pages; use the left and right keys to
switch steps.
When setting the steps, if there are static and overcurrent test steps,
the static test needs to be placed in the first step, and the overcurrent test needs to
be placed in the second step; if there is no static test but there is an overcurrent
test, the overcurrent test needs to be placed In the first step.
For other parameters, refer to the parameter setting methods on the pages of internal
resistance test, programmable load, and programmable power supply.