13
Meaning of each parameter:
Load mode:
This parameter has CC mode and CV mode optional. In CC mode, the
battery is discharged in constant current mode, and the load current parameter is valid; in
CV mode, the battery is discharged in constant voltage mode, and the load voltage
parameter effective.
Load voltage:
After this parameter is set, when the load mode is CV mode, the
instrument will discharge the battery at a constant voltage with the value set by this
parameter.
Load current:
After this parameter is set, when the load mode is CC mode, the
instrument will discharge the battery with constant current at the value set by this
parameter.
Cut-off voltage:
After this parameter is set, the instrument will use this parameter to
interrupt the battery discharge operation.
After setting all parameters, connect the battery to be tested, press the function key
corresponding to the OFF switch at the bottom right corner of the screen, and the switch
will turn from OFF to ON to start the battery discharge operation; if you want to interrupt
the discharge operation in the middle, press again Press this function key and the switch
will turn from ON to OFF, which can interrupt the discharging operation of the battery. The
discharge capacity will be recorded in real time during the test
CV mode selection: When the overcurrent value is greater than 2.5 times the actual
working current value or the overcurrent value is greater than 10A, select this mode.
The test speed in this mode is fast, but some batteries may not support this mode.
If the test overcurrent value in this mode is 0, it is recommended to use the CC
mode.
CC mode selection: Otherwise, select this mode.