6.2.1
Inspection during storage
1.
Turn the shaft every three months and just before putting into operation
7
Installation instructions
7.1
Setting up the pump
ATTENTION
Make sure that the pump conne-ctions are not over-stressed
at the inlet and outlet connectio-ns.Please see the table below.
11
Allowable force DL
DL2.4
25
9400
3200
3200
10400
DL4.8
25
9400
3200
DL8
40
9400
3200
DL12
65
11000
2000
6500
12900
DL18
65
11000
2000
6500
12900
DL120
100
60000
40000
40000
82500
3200
3200
10400
10400
type
DN[mm]
Force[N]
Fx
Fy
Fz
F
12
Table 12:Allowable torque DL
DL2.4
DL4.8
DL8
DL12
DL18
Dl120
25
600
600
600
460
460
3600
25
40
65
65
100
type
DN[mm]
Force[N]
Fx
Fy
Fz
F
300
300
300
460
460
6100
360
360
360
1000
1000
4800
800
800
800
1200
1200
8600
ATTENTION
For the values mentioned in the tables above,it is assumed
that they occur simultaneously
ATTENTION
Pumps which do not stand steady or stable on their own,
should be mounted on a rigid and stable base.
ATTENTION
Locate the pump at the place with the lowest risk for noise
nuisance.
1. ,
,
Place and install the pump on a level, stable surface in a dry and
frost-free room.
2.
1/ 4
Make sure thst sufficient air can reach the cooling fan of the motor.
For this purpose the free space above the cooling fan should be at
least 1/4 of the diameter of the fan cover air intake.
6
Figure 6:Allowable forces