5.1 Ignition Power Management Quick Guide
Startup/shutdown conditions from the IGNITION signal:
◆
IGNITION startup signal must be valid during 3 sec. (anti
‐
noise protection).
◆
IGNITION shutdown – IGNITION signal must be inactive during 3 Sec, then PIC
controller initiate Power Button signal (
OS must be set to shut down from the
Power Button
). It generate Main Button shutdown event and then goes to
complete power off.
Typically the system can start only from IGNITION signal, because startup PIC controller is
disconnected from the power source.
The system can be switched off from:
◆
Power IGNITION OFF signal.
◆
ACPI OS shutdown
◆
Power Button – generate ACPI event (OS dependent).
Power Ignition Startup Procedure
Power Ignition Shutdown Procedure