![Jetting TriggAIR Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/jetting/triggair/triggair_user-manual_3860267013.webp)
13
9. Troubleshooting guide
Fiber becomes jammed in the duct
1. Inform the people at the other end of the pipe that a
problem has been experienced and the operator is
going to shut down the system.
2. Shut off the air supply with the air control valve, allowing
the air pressure to be depressurized from the duct and
the duct clamp air block.
3. Using the counter or the measurement on the fiber cable,
determine where the blockage might be located.
4. Notify supervisor about problem and determine a
solution
accordingly.
Wheels does not pull the fiber
1. Assist the reel by pushing the cable of the reel.
2.
Adjust
the
clamping
force.
Hard to restart after stop
1. Put more/less air to the system.
2. The wheel can be restarted after the air pressure has
increased and stabilized.
Wheel feed does not start
1. Battery is low, check battery indicator.
Содержание TriggAIR
Страница 1: ...TriggAIR Product model type TriggAIR TriggAIR USER S GUIDE AND SAFETY MANUAL ...
Страница 14: ...14 10 EC Declaration of Conformity ...
Страница 15: ...15 11 Notes ...