background image

6. Crash test

Fiber Crash Testing is a very quick and easy step to be completed before attempting the installation of 
fiber cable with the TriggAIR. This test is necessary to set the pushing force control of the motor below 
the point that the TriggAIR may cause fibre damage as a result of over pushing or encountering an  
obstruction in the sub-duct system.

Every fiber has different pushing values and these values vary depending on duct I.D.

  Always wear protective equipment: hard 
 

 

hat, safety glasses, safety shoes and work gloves.

IMPORTANT
For the Crash Test to work properly, use the same size fiber and pipe that will be used for the job. Jetting 
cannot be responsible for any fiber damages.

Crash Test: For all types of fibers > 0,5 mm diameter

1. 

Insert the fiber and seal inside the duct as it would be for the actual installation.

2. 

Install a 1 to 2m test length of duct into the TriggAIR clamp.

3. 

Block the end of the test length of duct.

4. 

Tighten the wheel pressure on to the fibre with the wheel drive engaged in the forward direction  

 

until the fibre starts to install.

5.  

Ram the fiber into the blocked end of the duct.

6. 

Fibre cable should stop before the fiber folds over/are damaged. If the fibre cable do not stop  

 

go to 7.

7. 

Reduce the adjustable clutch for fibre security.

8. 

Repeat step 6-7 until the fiber folds. This is your push force slip limit.

9.  

Loosen up the wheel on the fiber a quarter turn and perform test once more to confirm no fold  

 

over has occurred. KEEP THIS SETTING APPLIED TO THE FIBER FOR ACTUAL INSTALLATION!

10. 

Swap out test length of pipe with actual installation duct and proceed to operating the TriggAIR.

10

Содержание TriggAIR

Страница 1: ...TriggAIR Product model type TriggAIR TriggAIR USER S GUIDE AND SAFETY MANUAL ...

Страница 2: ...orm or by any means including photocopying recording or other electronic or mechanical methods without the prior written permission of the publisher For permission requests write to the publisher addressed Attention Permissions Coordinator at the address below Jetting AB Murgatan 1 522 35 Tidaholm Sweden jetting se info jetting se ...

Страница 3: ...y information on this page and note specific safety requirements as explained by procedures in this manual Failure to follow these instructions could result in serious personal injury or death 3 Caution Noise will exceed 70 db Manufacturer Jetting AB Murgatan 1 522 35 Tidaholm Sweden jetting se info jetting se 46 502 65 90 10 ...

Страница 4: ...echnical information 2 6 Safe operating practices 3 7 Unpacking the box 4 8 Set up the TriggAIR 5 8 Crash test 6 10 Blower operations 7 11 Maintenance 8 12 Troubleshooting guide 9 13 EC Declaration of Conformity 10 14 Notes 11 15 Section Page 4 ...

Страница 5: ... in two halves that clamp together around the duct The duct clamp holds a seal that the fiber optic fibre is feed through before entering the duct The duct clamp can be used for both 5 0 and 7 0 mm ducts Fiber seals can be interchanged to accommodate different fibre sizes The duct is mechanically clamped between the duct clamps at the exit of the duct clamp preventing movement in any direction Sea...

Страница 6: ...ed Adjustable 0 150 m min 3 Fiber sizes 0 5 mm to 3 0 mm 4 Duct sizes 5 0 and 7 0 mm D Electrical requirements 1 Power requirements Volt max 12 V 4 0 Ah 2 Power connection Milwaukee standard E Physical specifications 1 Height 260 mm 2 Length 200 mm 3 Width 120 mm 4 Weight 2 3 kg F Wheel drive specifications 1 Adjustable clamp force G Pipecoupling requirements 1 Must withstand maximum air pressure ...

Страница 7: ...e and conduit 7 Use the blower only for its intended purpose 8 Do not place fiber reel too close to unit Place the reel far enough away from the unit to ensure proper control 9 Keep hands away from belt drive while blower is in operation B Electrical devices The motor controller and digital display are electrical devices Electrical shock hazards exist that could result in severe personal injury or...

Страница 8: ...Batteries Battery Charger Robust protecting case Cable Seal Box User manual B Accessories Arm for preconnected fibre Tripod incl CEJN adaptor Table Bracket for mounting on Table 8 5 Set up the TriggAIR This manual contains setup and operating instructions for the TriggAir Do not connect power supply until setup is complete Behöver en bättre bild Behöver en bättre bild ...

Страница 9: ... clamp force wheel using the screw knob to ensure even pressure on the fibre cable Do not over tighten F Adjust clutch for fibre security Adjust if needed tighten it by turning the knob right and loosing it by turning left G Connect battery to blowing unit H Connect air compressor NOTE Ensure the air control valve is off before connecting the air hose Attach the air compressor hose to the air comp...

Страница 10: ... of fibers 0 5 mm diameter 1 Insert the fiber and seal inside the duct as it would be for the actual installation 2 Install a 1 to 2m test length of duct into the TriggAIR clamp 3 Block the end of the test length of duct 4 Tighten the wheel pressure on to the fibre with the wheel drive engaged in the forward direction until the fibre starts to install 5 Ram the fiber into the blocked end of the du...

Страница 11: ... 16 bars when operating the unit Forced air creates flying debris Always wear personal protective equipment Motor is not covered by warranty if motor is overheated When exceeding maximum pushing force clutch fully engaged let the motor cool down between the cycles 4 Adjust speed Use the button to adjust the drive speed to ensure smooth installation and match the amount of air pressure being used s...

Страница 12: ...s no longer able to effectively grip the fiber optic fiber X Duct pack seal replacement X Seals replacement Inspect seal before each use Wheel cleaning and tightening Inspect wheel and tighten before and after each use Clean after each use or when necessary Disconnect power supply and exhaust any air pressure before servicing any component on the TriggAIR Avoid handling leaking couplings valve sea...

Страница 13: ...e duct clamp air block 3 Using the counter or the measurement on the fiber cable determine where the blockage might be located 4 Notify supervisor about problem and determine a solution accordingly Wheels does not pull the fiber 1 Assist the reel by pushing the cable of the reel 2 Adjust the clamping force Hard to restart after stop 1 Put more less air to the system 2 The wheel can be restarted af...

Страница 14: ...14 10 EC Declaration of Conformity ...

Страница 15: ...15 11 Notes ...

Страница 16: ...TriggAIR USER S GUIDE AND SAFETY MANUAL Version 2021 12 ...

Отзывы: